Screw Counter Reset Icon on Monitoring Screen
8. RPM Setting
The fastening speed or RPM can be adjusted from 200rpm to 1000rpm. Press on the
numerical value to activate keypad.
9. Screw Seating Stability Control
Press YES to activate seating stability control, this function will stabilize the fastening
process right before the seating of the screw to enhance fastening torque accuracy.
When this function is activated, the screwdriver will slow down to the RPM of which
can be adjusted below, when it reaches either the minimum turns or the minimum
time, depending on which mode the user has selected (please refer to the previous
pages for detection method)
RPM Setting for Stability Control
Please note that if the user activates the stability control, torque calibration must
also be done with the stability control turned on, the result of the calibration
varies between activation and deactivation of the stability control (slow and high
speed).
10. Target Torque Offset
Displayed torque offset setting is for the user to manually adjust the displayed torque
on the system (Control Unit) when there is a constant amount of disparity between the
torque value displayed on the system and the value displayed on a benchmark such as
63