Description
Exceeds Max. Torque
Min. Torque Not Attained
Exceeds Max. Time
Min. Time Not Attained
Exceeds Max. Turns
Min. Turns Not Attained
11. Advanced System Lock Settings
The user can choose to deactivate the system lock through I/O or external scanners,
press no to skip the setting. This function is useful when a scanner is used on the work
piece before fastening process begins (if the scanner detects a wrong work piece on
the assembly line), or an I/O signal is sent from an automation system to begin
fastening. If I/O or Scan is chosen, the user can also choose whether a password is
needed to unlock the system.
System Lock
Function
System lock activated when torque exceeds the upper limit of torque
setting
System lock activated when torque attained is less than the lower
limit of torque setting
System lock activated when the fastening process takes longer than
the upper limit of the time setting
System lock activated when the duration of the fastening process is
shorter than the lower limit of the time setting
System lock activated when the number of turns (revolution)
exceeds the upper limit
System lock activated when the number of turns is lower than the
lower limit