5-11. Making Dual Operator CC And CV Weld Connections w/ Separate Work Cables
A. 700 And 700X Duo Pro Models
Welder A (Left) Side
2
!
Stop engine.
NOTICE − Do not exceed machine duty
cycle.
.
Use Dual Operator mode for CC and
CV welding (see Section 6-2).
See Section 5-14 for proper cable size.
1
Electrode Holder Cable
2
Wire Feeder Cable
3
Work Cables
OM-252624 Page 36
.
Complete Parts List available at www.MillerWelds.com
.
Optional Weld Selector switch shown.
Direct Current Electrode Positive
(DCEP) connections are shown.
For Stick/TIG welding Direct Current Elec-
trode Positive (DCEP), connect work
cable to Negative (−) terminal and elec-
trode holder cable to Positive (+) terminal.
For Stick/TIG Direct Current Electrode
Negative (DCEN), connect work cable to
Positive (+) terminal and electrode holder
cable to Negative (−) terminal.
.
Be sure Process Selector switches
are set correctly. See Section 6-3.
1
3
For MIG and FCAW welding Direct Current
Electrode Positive (DCEP), connect work
cable to Negative (−) terminal and wire
feeder cable to Positive (+) terminal.
For MIG and FCAW Direct Current Elec-
trode Negative (DCEN), connect work
cable to Positive (+) terminal and wire feed-
er cable to Negative (−) terminal.
.
Be sure Process Selector switches
are set correctly. See Section 6-3.
Tools Needed:
3/4 in.
Welder B (Right) Side
3
Ref. 251 340-A / Ref. 802 292-A