Installing Exhaust Pipe - Miller Big Blue 700 Duo Pro DLX SF Owner's Manual

Hide thumbs Also See for Big Blue 700 Duo Pro DLX SF:
Table of Contents

Advertisement

5-2. Grounding Generator To Truck Or Trailer Frame
!
Always ground generator frame to
vehicle frame to prevent electric
shock and static electricity hazards.
!
Also see AWS Safety & Health Fact
Sheet No. 29, Grounding of Portable
And Vehicle Mounted Welding Gen-
erators.
!
Bed liners, shipping skids, and
some running gear insulate the
welding generator from the vehicle

5-3. Installing Exhaust Pipe

Tools Needed:
1/2 in
.
Complete Parts List available at www.MillerWelds.com
1
GND/PE
frame. Always connect a ground
wire from the generator equipment
grounding terminal to bare metal on
the vehicle frame as shown.
!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord. Do
not use GFCI receptacles to power
life support equipment.
2
3
1
Equipment Grounding Terminal (On
Front Panel)
2
Grounding Cable (Not Supplied)
3
Metal Vehicle Frame
Connect cable from equipment ground
terminal to metal vehicle frame. Use #8
AWG or larger insulated copper wire.
.
Electrically bond generator frame to ve-
hicle frame by metal-to-metal contact.
!
.
Exhaust1 2014−10 Ref. 803 604 / Ref. 215 664
rot_grnd2 2014−11 − 800 652-D
Stop engine and let cool.
Point exhaust pipe in desired di-
rection but always away from front
panel and direction of travel.
OM-252624 Page 27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Big blue 700x duo pro dlx sf

Table of Contents