Troubleshooting - Miller Big Blue 700 Duo Pro DLX SF Owner's Manual

Hide thumbs Also See for Big Blue 700 Duo Pro DLX SF:
Table of Contents

Advertisement

8-10. Troubleshooting

.
Also see Voltmeter/Ammeter help displays to assist in troubleshooting weld problems (see Section 8-9).
A. Welding
Trouble
No weld output; generator power output
okay at AC receptacles.
No weld output or generator power out-
put at AC receptacles.
Erratic weld output.
High weld output.
Low weld output.
Low open-circuit voltage.
No remote fine amperage or voltage
control.
Constant speed wire feeder does not
work.
Low CV weld output.
.
Complete Parts List available at www.MillerWelds.com
Place Process/Contactor switch in an Electrode Hot position, or place switch in a Remote On/Off Re-
quired position and connect remote contactor to Remote 14 receptacle (see Sections 5-15).
Reset supplementary protector CB3 (see Section 8-8).
Reset supplementary protector CB9 and/or CB29 (see Section 8-8). Check for faulty remote device
connected to Remote 14 receptacle.
Check and secure connections to Remote 14 receptacle (see Section 5-15).
Have Factory Authorized Service Agent check filter board PC5 and/or PC25 and connections.
Check fuse F2, and replace if open (see Section 8-8). Have Factory Authorized Service Agent check
brushes and slip rings, weld excitation circuit, and the rotor.
Disconnect equipment from generator power receptacles during start-up.
Reset supplementary protector CB4.
Check fuses F1 and F2, and replace if open (see Section 8-8). Have Factory Authorized Service Agent
check integrated rectifier SR2, capacitor C6, and the rotor.
Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.
Check and tighten connections inside and outside unit.
Be sure connection to work piece is clean and tight.
Use dry, properly stored electrodes.
Remove excessive coils from weld cables.
Have Factory Authorized Service Agent check brushes and slip rings.
Check position of Voltage/Amperage Adjust control.
Check engine speed, and adjust if necessary.
Have Factory Authorized Service Agent check voltage feedback circuit.
Check position of Voltage/Amperage Adjust control.
Check engine speed, and adjust if necessary.
Check fuses F1 and F2, and replace if open (see Section 8-8). Have Factory Authorized Service Agent
check integrated rectifier SR2, capacitor C6, and the rotor.
Check engine speed, and adjust if necessary.
Check position of Process/Contactor switch.
Check and secure connections to Remote 14 receptacle (see Section 5-15).
Repair or replace remote control device.
Have Factory Authorized Service Agent check current sensing devices, and connections.
Reset supplementary protector CB9 or CB29 (see Section 8-8).
Check and secure connections to Remote 14 receptacle (see Section 5-15).
Repair or replace wire feeder.
Increase Voltage/Amperage Adjust Control setting.
Remedy
OM-252624 Page 61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Big blue 700x duo pro dlx sf

Table of Contents