Operation - Scholl 3010 UA Instructions For Use Manual

Bain-marie free standing
Table of Contents

Advertisement

GBA H 2000 1 E
5
O
PERATION
Bain-Marie with continuously heated basin:
The Bain-Marie has a thermostat and an indicator lamp.
The thermostat switches the heating on and off and set the temperature.
Bain-Marie with continuously heated basin (Model-No. 3010 UA, 3021 UA):
The Bain-Marie has a switch with indicator lamp and a thermostat.
The switch with indicator lamp switches the unit on and off.
The thermostat sets the temperature.
Bain-Marie with separately heated basins:
For each basin, the Bain-Marie has a dedicated thermostat and a dedicated indicator lamp.
The thermostats switch the respective heatings on and off and set the temperatures.
Thermostat off
Thermostat on
Indicator lamp lit
Indicator lamp dark
Only for Model-No. 3010 UA and 3021 UA:
Switch with indicator lamp
Switch on
Switch off
BA
Last revised 01-2018
Position "0"
(Number "0" is below the mark)
Position "1" to "10"
(Number "1" to "10" is below the mark)
Heating on
Heating off
Indicator lamp lit
Indicator lamp dark