Possible Malfunctions - Scholl 3010 UA Instructions For Use Manual

Bain-marie free standing
Table of Contents

Advertisement

GBA H 2000 1 E
7.1
P
OSSIBLE MALFUNCTIONS
Malfunction
Bain-Marie does not heat
Bain-Marie
food is not warm enough
BA
Last revised 01-2018
Cause
No voltage supply
Defective plug/electrical cord
Overheating protection has
switched off the Bain-Marie.
Operating error:
Bain-Marie was used drily with-
out water.
Tthermostat defective
Heating defective
Model-No. 3010 UA, 3021 UA:
Switch with indicator lamp
defective
Operating error:
GN-inset is not high enough
Page 17 of 35
Remedy
Check voltage supply
DANGER!
Hazardous electrical voltage.
Pull out the mains plug and bar
product from further use.
To be remedied by an electrical
specialist.
Let the device cool off until the
overheating protection that is
on the adhesive foil heating
switches off again on its own.
Bain-Marie filling level: 20-
30mm water
Replace thermostat
Replace heating
Replace switch with indicator
lamp
Use GN-inset 200mm high,
Bain-Marie filling level: 20-
30mm water
Januar 17, 2018
Rev. 1

Advertisement

Table of Contents
loading

Table of Contents