Technical Data; Execution - Scholl 3010 UA Instructions For Use Manual

Bain-marie free standing
Table of Contents

Advertisement

GBA H 2000 1 E
8
T
ECHNICAL DATA
8.1
E
XECUTION
 Chrome nickel steel 18/10
 Cover all around 40 mm folded
 Substructure with soild square tube (Model-No. 3010 UA, 3021 UA with tube),
feet with adjustable studs and 1 sound-absorbing base shelf
 Model UA:
Continuously heated basin, with removable lateral divider
Model UAG: Separately heated basins
 Model-No. 3010 UA, 3021 UA:
On front side switch panel with switch elements: switch with indicator lamp, thermostat
 Model-No. 3012 UA, 3013 UA, 3014 UA, 3015 UA, 3012 UAG, 3013 UAG, 3014 UAG, 3015 UAG:
On front side switch panel back set switch elements: thermostat, indicator lamp
 Bain-Marie basin indirectly heated,
adhesive foil heating with overheating protection under the basin bottom
 Thermostatically adjustable from 30-90°C
 Bain-Marie manual filling by hand
 Bain-Marie water drain with ball valve downwards
Drain 1/2": Model-No. 3010 UA, 3021 UA, 3012 UAG, 3013 UAG, 3014 UAG, 3015 UAG
Drain 3/4": Model-No. 3012 UA, 3013 UA, 3014 UA, 3015 UA
 E-connection on rear side:
230V: Connection cable approx. 2 m long, with Schuko plug
400V: Connection cable approx. 2 m long, with CEE 16A right angle plug
BA
Last revised 01-2018
Page 18 of 35
Januar 17, 2018
Rev. 1