Page 1 of 35
Art.-No.
H 2210
H 2310
H 2410
H 2510
Januar 17, 2018
Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Scholl 3010 UA

  • Page 1 H 2400 3014 UAG H 2410 3015 UA H 2500 3015 UAG H 2510 Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D–56470 Bad Marienberg/Germany Phone +0049 (0) 2661 – 9868-10 +0049 (0) 2661 – 9868-38 (Service) Internet www.scholl-gastro.de E-mail info@scholl-gastro.de...
  • Page 2: Table Of Contents

    GBA H 2000 1 E ABLE OF CONTENTS Table of contents ............................... 2 Preface ................................4 Conventions ............................... 5 Pictograms – General safety notes ....................5 Pictograms – Warning notes ......................7 Pictograms – Important notes ......................8 Product information ..........................9 Information regarding compliance with standards, laws and directives .........
  • Page 3 GBA H 2000 1 E Technical data............................18 Execution ............................18 8.1.1 Execution continuously heated basin ..................19 8.1.2 Execution separately heated basins ..................19 Dimensioned drawings ........................20 8.2.1 Dimensioned drawing H 2000 ....................20 8.2.2 Dimensioned drawing H 2100 ....................21 8.2.3 Dimensioned drawing H 2200 ....................
  • Page 4: Preface

    REFACE Congratulations! In purchasing this new SCHOLL appliance you have chosen a product which meets highest technical stand- ards while providing outstanding convenience in practical use. This appliance has been designed with minimal energy consumption in mind. Used responsibly, it will serve you well in an ecologically sound manner.
  • Page 5: Conventions

    GBA H 2000 1 E ONVENTIONS – G ICTOGRAMS ENERAL SAFETY NOTES Be sure to observe these Instructions for Use as well as the safety notes to prevent injuries or damage to health or property. Do not alter or modify this appliance. Never use a defective appliance.
  • Page 6 Connecting the unit to the mains with its thermostat switch not set to „0“ may cause accidents. Only for Model-No. 3010 UA, 3021 UA: Do not allow this appliance to operate unattended. Ensure that the switch with indicator lamp and the dimmer is set to „0“ before inserting the plug into an electri- cal socket-outlet or connecting the appliance to the power supply.
  • Page 7: Pictograms - Warning Notes

    GBA H 2000 1 E – W ICTOGRAMS ARNING NOTES Cleaning must only be performed by qualified persons who have read and under- stood these Instructions for Use and are familiar with applicable hygiene rules. En- sure that care is exercised during cleaning of the unit. For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water which contains a small amount of dishwashing detergent.
  • Page 8: Pictograms - Important Notes

    GBA H 2000 1 E – I ICTOGRAMS MPORTANT NOTES DANGER indicates an immediately threatening hazard. Failure to observe this warning notice will result in severe physical injury or death. WARNING indicates a potentially dangerous situation. Failure to observe this warning notice may result in severe physical injury or death.
  • Page 9: Product Information

    GBA H 2000 1 E RODUCT INFORMATION Bain-Maries are electrically heated warm retaining basins. Bain-Maries are operated with water and are used for keeping warm preheated food at output temperature. Bain-Maries are feeded from above with GN-insets in accordance with DIN EN 631-1. NFORMATION REGARDING COMPLIANCE WITH STANDARDS LAWS AND DIRECTIVES Standards, laws, directives...
  • Page 10: Packing, Transport, Intermediate Storage, Scope Of Delivery

    GBA H 2000 1 E ACKING TRANSPORT INTERMEDIATE STORAGE SCOPE OF DELIVERY ACKING The type of packing employed will depend, to a large extent, on the adopted shipping mode and route. Except where otherwise agreed by contract, packing will conform to the "HPE Packing Guideline" defined by the German Federal Association of the Wooden Materials, Pallets and Export Packing Industry and by the German Engineering Federation.
  • Page 11: Installation And Electrical Installation

    GBA H 2000 1 E NSTALLATION AND ELECTRICAL INSTALLATION NSTALLATION Before the installation of the appliance, observe the following:  Inspect the unit for any defect or damage sustained in transit.  Check all screw connections for tightness.  Familiarize yourself with the Instructions for Use and with the conditions for the safe operation of this appliance.
  • Page 12: Operation

    The Bain-Marie has a thermostat and an indicator lamp. The thermostat switches the heating on and off and set the temperature. Bain-Marie with continuously heated basin (Model-No. 3010 UA, 3021 UA): The Bain-Marie has a switch with indicator lamp and a thermostat.
  • Page 13: Intended Use

     Fill the Bain-Marie basin manually with water, fill level approx. 20-30 mm. Only Model-No. 3010 UA and 3021 UA: Fill level approx. 10 mm above fill mark.  Only Model-No. 3010 UA and 3021 UA: Switch on the switch with indicator lamp.
  • Page 14: Maintenance

    GBA H 2000 1 E AINTENANCE AINTENANCE AND REPAIR Maintenance and repairs on the appliance must only be carried out by an author- ized professional observing applicable safety regulations. Improperly executed work will put your safety at risk! Before any cleaning, maintenance or repair work is carried out, the appliance must be disconnected from the mains and de-energized.
  • Page 15 GBA H 2000 1 E Cleaning must only be performed by qualified persons who have read and under- stood these Instructions for Use and are familiar with applicable hygiene rules. En- sure that care is exercised during cleaning of the unit. For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water containing a small amount of dishwashing detergent.
  • Page 16: Troubleshooting

    GBA H 2000 1 E ROUBLESHOOTING Repairs must be carried out by an authorized specialist in compliance with applica- ble safety codes and regulations. Improperly executed work will put your safety at risk! Note that some work must only be carried out by an electrical specialist. According to DIN EN 60204-1: 2011-01, specialists are „persons who by reason of their relevant training and experience are capable of recognizing risks and avoiding potential hazards."...
  • Page 17: Possible Malfunctions

    Bain-Marie was used drily with- Bain-Marie filling level: 20- out water. 30mm water Tthermostat defective Replace thermostat Heating defective Replace heating Model-No. 3010 UA, 3021 UA: Switch with indicator lamp Replace switch with indicator defective lamp Bain-Marie Operating error: Use GN-inset 200mm high,...
  • Page 18: Technical Data

     Bain-Marie manual filling by hand  Bain-Marie water drain with ball valve downwards Drain 1/2": Model-No. 3010 UA, 3021 UA, 3012 UAG, 3013 UAG, 3014 UAG, 3015 UAG Drain 3/4": Model-No. 3012 UA, 3013 UA, 3014 UA, 3015 UA ...
  • Page 19: Execution Continuously Heated Basin

    GBA H 2000 1 E 8.1.1 E XECUTION CONTINUOUSLY HEATED BASIN Model-No. Art.-No. Length Depth Height GN-insets Voltage Power 3010 UA H 2000 360 mm 560 mm 850 mm 1 x 1/1- 230 V 1 kW 3021 UA H 2100 560 mm...
  • Page 20: Dimensioned Drawings

    GBA H 2000 1 E IMENSIONED DRAWINGS Dimensioned drawings are available upon request. 8.2.1 D H 2000 IMENSIONED DRAWING Model-No. Art.-No. 3010 UA H 2000 Page 20 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 21: Dimensioned Drawingh 2100

    GBA H 2000 1 E 8.2.2 D H 2100 IMENSIONED DRAWING Model-No. Art.-No. 3021 UA H 2100 Page 21 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 22: Dimensioned Drawingh 2200

    GBA H 2000 1 E 8.2.3 D H 2200 IMENSIONED DRAWING Model-No. Art.-No. 3012 UA H 2200 Page 22 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 23: Dimensioned Drawingh 2210

    GBA H 2000 1 E 8.2.4 D H 2210 IMENSIONED DRAWING Model-No. Art.-No. 3012 UAG H 2210 Page 23 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 24: Circuit Diagrams

    Circuit diagrams are available upon request. 8.3.1 C IRCUIT DIAGRAMS CONTINUOUSLY HEATED BASIN 8.3.1.1 C H 2000 H 2100 IRCUIT DIAGRAM Model-No. Art.-No. 3010 UA H 2000 3021 UA H 2100 Key: Switch with indicator lamp Thermostat Heating with overheat protection Page 24 of 35...
  • Page 25: Circuit Diagramh 2200

    GBA H 2000 1 E 8.3.1.2 C H 2200 IRCUIT DIAGRAM Model-No. Art.-No. 3012 UA H 2200 Key: Thermostat R1-R2 Heating with overheat protection Indicator lamp Page 25 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 26: Circuit Diagramh 2300

    GBA H 2000 1 E 8.3.1.3 C H 2300 IRCUIT DIAGRAM Model-No. Art.-No. 3013 UA H 2300 Key: Thermostat R1-R3 Heating with overheat protection Indicator lamp Page 26 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 27: Circuit Diagramh 2400

    GBA H 2000 1 E 8.3.1.4 C H 2400 IRCUIT DIAGRAM Model-No. Art.-No. 3014 UA H 2400 Key: Thermostat R1-R4 Heating with overheat protection Indicator lamp Page 27 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 28: Circuit Diagramh 2500

    GBA H 2000 1 E 8.3.1.5 C H 2500 IRCUIT DIAGRAM Model-No. Art.-No. 3015 UA H 2500 Key: Thermostat R1-R5 Heating with overheat protection Indicator lamp Page 28 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 29: Circuit Diagrams Separately Heated Basins

    GBA H 2000 1 E 8.3.2 C IRCUIT DIAGRAMS SEPARATELY HEATED BASINS 8.3.2.1 C H 2210 IRCUIT DIAGRAM Model-No. Art.-No. 3012 UAG H 2210 Key: S1-S2 Thermostat R1-R2 Heating with overheat protection H1-H2 Indicator lamp Page 29 of 35 Januar 17, 2018 Last revised 01-2018 Rev.
  • Page 30: Circuit Diagramh 2310

    GBA H 2000 1 E 8.3.2.2 C H 2310 IRCUIT DIAGRAM Model-No. Art.-No. 3013 UAG H 2310 Key: S1-S3 Thermostat R1-R3 Heating with overheat protection H1-H3 Indicator lamp Page 30 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 31: Circuit Diagramh 2410

    GBA H 2000 1 E 8.3.2.3 C H 2410 IRCUIT DIAGRAM Model-No. Art.-No. 3014 UAG H 2410 Key: S1-S4 Thermostat R1-R4 Heating with overheat protection H1-H4 Indicator lamp Page 31 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 32: Circuit Diagramh 2510

    GBA H 2000 1 E 8.3.2.4 C H 2510 IRCUIT DIAGRAM Model-No. Art.-No. 3015 UAG H 2510 Key: S1-S5 Thermostat R1-R5 Heating with overheat protection H1-H5 Indicator lamp Page 32 of 35 Januar 17, 2018 Last revised 01-2018 Rev. 1...
  • Page 33: Disposal And Environmental Notes

    GBA H 2000 1 E ISPOSAL AND NVIRONMENTAL OTES The appliance has been packed before shipping to protect it against damage in transit. After unpacking, please dispose of packing materials in an environmentally sound manner. All packing materials are eco-compatible, 100% recyclable and marked with a sym- bol to that effect.
  • Page 34: Warranty And Service

    GBA H 2000 1 E ARRANTY AND SERVICE 10.1 W ARRANTY CONDITIONS The manufacturer accepts no liability or warranty in the following cases:  failure to observe notes and instructions given in the Instructions for Use;  use of the product in a manner not conforming to its intended use; ...
  • Page 35: Service Address

    7:00 a.m. till 4:00 p.m. Fridays from 7:00 a.m. till 12:15 p.m. Outside these office hours please communicate your requests per e-mail or telefax. Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D-56470 Bad Marienberg/Germany Phone 0049 (0)2661/9868-10...