GBA G 1101 4 E ABLE OF CONTENTS Table of contents ............................... 2 Preface ................................5 Conventions ............................... 6 Pictograms – General safety notes ....................6 Pictograms – Warning notes ......................7 Pictograms – Important notes ......................8 Product information ..........................9 Execution of size 31 Bain-Marie ZAÜ...
Page 3
GBA G 1101 4 E Troubleshooting ............................18 Possible malfunctions ........................19 Technical data............................20 Technical data size 31 Bain-Marie ZAÜ, continuously heated ............20 Technical data size 31 Bain-Marie ZAÜ, separately heated ............20 Technical data size 32 Bain-Marie ZAÜ, continuously heated ............21 Technical data size 32 Bain-Marie ZAÜ, separately heated ............
Page 4
GBA G 1101 4 E Circuit diagrams ..........................38 10.1 Circuit diagrams Bain-Marie ZAÜ, continuously heated ..............38 10.1.1 Circuit diagram Bain-Marie ZAÜ, continuously heated, GN 1 x 1/1 ........38 10.1.2 Circuit diagram Bain-Marie ZAÜ, continuously heated, GN 2 x 1/1 ........39 10.1.3 Circuit diagram Bain-Marie ZAÜ, continuously heated, GN 3 x 1/1 ........
REFACE Congratulations! In purchasing this new SCHOLL appliance you have chosen a product which meets highest technical stand- ards while providing outstanding convenience in practical use. This appliance has been designed with minimal energy consumption in mind. Used responsibly, it will serve you well in an ecologically sound manner.
GBA G 1101 4 E ONVENTIONS – G ICTOGRAMS ENERAL SAFETY NOTES Be sure to observe these Instructions for Use as well as the safety notes to prevent injuries or damage to health or property. Do not alter or modify this appliance. Never use a defective appliance.
GBA G 1101 4 E – W ICTOGRAMS ARNING NOTES Cleaning must only be performed by qualified persons who have read and under- stood these Instructions for Use and are familiar with applicable hygiene rules. En- sure that care is exercised during cleaning of the unit. For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water which contains a small amount of dishwashing detergent.
GBA G 1101 4 E – I ICTOGRAMS MPORTANT NOTES DANGER indicates an immediately threatening hazard. Failure to observe this warning notice will result in severe physical injury or death. WARNING indicates a potentially dangerous situation. Failure to observe this warning notice may result in severe physical injury or death.
GBA G 1101 4 E RODUCT INFORMATION Bain-Maries are electrically heated warm retaining basins. Bain-Maries are operated with water and are used for keeping warm preheated food at output temperature. Bain-Maries are feeded from above with GN-insets in accordance with DIN EN 631-1. 31 B ZAÜ...
GBA G 1101 4 E NFORMATION REGARDING COMPLIANCE WITH STANDARDS LAWS AND DIRECTIVES This appliance conforms to the following: Standards, laws, directives 2014/35/EU Low Voltage Directive 2014/30/EU EMC Directive AFETY This appliance conforms to accepted technical rules and relevant safety codes. However, proper use of the appliance is a prerequisite for effectively preventing damage or accidents.
GBA G 1101 4 E ACKING TRANSPORT INTERMEDIATE STORAGE SCOPE OF DELIVERY ACKING The type of packing employed will depend, to a large extent, on the adopted shipping mode and route. Except where otherwise agreed by contract, packing will conform to the "HPE Packing Guideline" defined by the German Federal Association of the Wooden Materials, Pallets and Export Packing Industry and by the German Engineering Federation.
GBA G 1101 4 E NSTALLATION ZAÜ NSTALLATION ARIE AND THERMOSTAT BUILT IN CASING Practice: Prepare cut-out for Bain-Marie in on site worktop. Prepare cut-out for thermostat built-in casing in on site counter top. Remove the toggle from the thermostat built-in casing and screw off the front cover. ...
GBA G 1101 4 E LECTRICAL INSTALLATION The appliance may only be installed by a qualified electrician whilst taking into account the applicable regulations! Connect this appliance to suitably earthed mains outlets only. Ensure that your mains power supply conforms to the data stated on the nameplate of the appliance. Failure to observe this warning may result in a fire hazard or electrical shock! Before putting the appliance into service, observe the following: ...
GBA G 1101 4 E PERATION For each basin, the Bain-Marie has a dedicated thermostat and a dedicated indicator lamp. The thermostat switches the Bain-Marie on and off and sets the temperature: Thermostat off Position "0" (number "0" is below the mark) Thermostat on Position "1"...
GBA G 1101 4 E ZAÜ NINTENDED USE ARIE Please observe strictly: Bain-Maries are for defrosting/warming up of deep-frozen/cooled food. Bain-Maries are for cooking food. Bain-Marie must be used without water! Bain-Marie must be used with any liquids other than water! Page 15 of 47 Januar 15, 2018 Last revised 01-2018...
GBA G 1101 4 E AINTENANCE AINTENANCE AND REPAIR Maintenance and repairs on the appliance must only be carried out by an author- ized professional observing applicable safety regulations. Improperly executed work will put your safety at risk. Before any cleaning, maintenance or repair work is carried out, the appliance must be disconnected from the mains and de-energized.
Page 17
GBA G 1101 4 E For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water containing a small amount of dishwashing detergent. Follow this up by wiping with clear water until no cleaning agent residue remains on the surface, as the latter might cause discoloration or stains.
GBA G 1101 4 E ROUBLESHOOTING Repairs must be carried out by an authorized specialist in compliance with applica- ble safety codes and regulations. Improperly executed work will put your safety at risk! Note that some work must only be carried out by an electrical specialist. According to DIN EN 60204-1: 2011-01, specialists are „persons who by reason of their relevant training and experience are capable of recognizing risks and avoiding potential hazards."...
GBA G 1101 4 E OSSIBLE MALFUNCTIONS Malfunction Cause Remedy Bain-Marie does not heat Overheating protection has Let the device cool off until the switched off the Bain-Marie. overheating protection that is Operating error: on the adhesive foil heating Bain-Marie was used drily with- switches off again on its own.
GBA G 1101 4 E ECHNICAL DATA 31 B ZAÜ, ECHNICAL DATA SIZE ARIE CONTINUOUSLY HEATED Basin rim folded 15 mm down all around Basin: continuously heated Depth: 630 mm Height: 280 mm Filling: on site Model-No. Length GN-insets Voltage Power Art.
GBA G 1101 4 E 32 B ZAÜ, ECHNICAL DATA SIZE ARIE CONTINUOUSLY HEATED Bain-Marie basin for flush fitting Basin: continuously heated Depth: 630 mm Height: 280 mm Filling: on site Model-No. Length GN-insets Voltage Power Art. No. 3211/ZAÜ 425 mm 1 x 1/1-200 230 V 1,0 kW...
GBA G 1101 4 E IMENSIONED DRAWINGS 31 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE CONTINUOUSLY HEATED 9.1.1 D 31 B ZAÜ, , GN 1 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3111/ZAÜ G 1101 Supply 1/2” with ball valve Drain 3/4"...
GBA G 1101 4 E 9.1.2 D 31 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3112/ZAÜ G 1201 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 23 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 9.1.3 D 31 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3113/ZAÜ G 1301 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 24 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 9.1.4 D 31 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3114/ZAÜ G 2401 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 25 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 31 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE SEPARATELY HEATED 9.2.1 D 31 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3112/2/ZAÜ G 1211 Supply 1/2” with ball valve Drain 3/4"...
GBA G 1101 4 E 9.2.2 D 31 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3113/3/ZAÜ G 1311 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 27 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 9.2.3 D 31 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3114/4/ZAÜ G 2411 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 28 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 32 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE CONTINUOUSLY HEATED 9.3.1 D 32 B ZAÜ, , GN 1 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3211/ZAÜ G 2101 Supply 1/2” with ball valve Drain 3/4"...
GBA G 1101 4 E 9.3.2 D 32 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3212/ZAÜ G 2201 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 30 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 9.3.3 D 32 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3213/ZAÜ G 2301 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 31 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 9.3.4 D 32 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3214/ZAÜ G 2501 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 32 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 32 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE SEPARATELY HEATED 9.4.1 D 32 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3212/2/ZAÜ G 2211 Supply 1/2” with ball valve Drain 3/4"...
GBA G 1101 4 E 9.4.2 D 32 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3213/3/ZAÜ G 2311 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 34 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 9.4.3 D 32 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3214/4/ZAÜ G 2511 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 35 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 32 B ZAÜ OUT DIMENSIONS SIZE ARIE Model-No. Length GN-insets Art. No. Cut-out size 3111/ZAÜ G 1101 425 mm 1 x 1/1-200 400 mm x 605 mm 3211/ZAÜ G 2101 3112/ZAÜ G 1201 3112/2/ZAÜ G 1211 770 mm 2 x 1/1-200 745 mm x 605 mm...
GBA G 1101 4 E HERMOSTAT WITH BUILT IN CASING Built-in casing with 2 cable screw connections Built-in casing with 1 cable screw connection for continuously heated basins for separately heated basins Cut-out size: 55 mm x 120 mm Installation depth: approx.
GBA G 1101 4 E IRCUIT DIAGRAMS 10.1 C ZAÜ, IRCUIT DIAGRAMS ARIE CONTINUOUSLY HEATED 10.1.1 C ZAÜ, , GN 1 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3111/ZAÜ G 1101 3211/ZAÜ G 2101 Key: Thermostat Heating incl. heat protection Indicator lamp Page 38 of 47 Januar 15, 2018...
GBA G 1101 4 E 10.1.2 C ZAÜ, , GN 2 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3112/ZAÜ G 1201 3212/ZAÜ G 2201 Key: Thermostat R1-R2 Heating incl. heat protection Indicator lamp Page 39 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 10.1.3 C ZAÜ, , GN 3 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3113/ZAÜ G 1301 3213/ZAÜ G 2301 Key: Thermostat R1-R3 Heating incl. heat protection Indicator lamp Page 40 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 10.1.4 C ZAÜ, , GN 4 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3114/ZAÜ G 2401 3214/ZAÜ G 2501 Key: Thermostat R1-R4 Heating incl. heat protection Indicator lamp Page 41 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 10.2 C ZAÜ, IRCUIT DIAGRAMS ARIE SEPARATELY HEATED 10.2.1 C ZAÜ, , GN 2 IRCUIT DIAGRAM ARIE SEPARATELY HEATED Model No. Art. No. 3112/2/ZAÜ G 1211 3212/2/ZAÜ G 2211 Key: S1-S2 Thermostat R1-R2 Heating incl. heat protection H1-H2 Indicator lamp Page 42 of 47 Januar 15, 2018...
GBA G 1101 4 E 10.2.2 C ZAÜ, , GN 3 IRCUIT DIAGRAM ARIE SEPARATELY HEATED Model No. Art. No. 3113/3/ZAÜ G 1311 3213/3/ZAÜ G 2311 Key: S1-S3 Thermostat R1-R3 Heating incl. heat protection H1-H3 Indicator lamp Page 43 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E 10.2.3 C ZAÜ, , GN 4 IRCUIT DIAGRAM ARIE SEPARATELY HEATED Model No. Art. No. 3114/4/ZAÜ G 2411 3214/4/ZAÜ G 2511 Key: S1-S4 Thermostat R1-R4 Heating incl. heat protection H1-H4 Indicator lamp Page 44 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
GBA G 1101 4 E ISPOSAL AND NVIRONMENTAL OTES The appliance has been packed before shipping to protect it against damage in transit. After unpacking, please dispose of packing materials in an environmentally sound manner. All packing materials are eco-compatible, 100% recyclable and marked with a sym- bol to that effect.
GBA G 1101 4 E ARRANTY AND SERVICE 12.1 W ARRANTY CONDITIONS The manufacturer accepts no liability or warranty in the following cases: failure to observe notes and instructions given in the Instructions for Use; use of the product in a manner not conforming to its intended use; ...
7:00 a.m. till 4:00 p.m. Fridays from 7:00 a.m. till 12:15 p.m. Outside these office hours please communicate your requests per e-mail or telefax. Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D-56470 Bad Marienberg/Germany Phone 0049 (0)2661/9868-10...