Scholl 3111/ZAU Instructions For Use Manual

Built-in bain-marie
Table of Contents

Advertisement

Quick Links

GBA G 1101 4 E
Instructions for Use
Built-in Bain-Marie ZAÜ
with water supply, drain and overflow,
with extension for ball valve
Continuously heated basin
Model-No.
Art. No.
3111/ZAÜ
G 1101
3112/ZAÜ
G 1201
3113/ZAÜ
G 1301
3114/ZAÜ
G 2401
3211/ZAÜ
G 2101
3212/ZAÜ
G 2201
3213/ZAÜ
G 2301
3214/ZAÜ
G 2501
Size 31 Bain-Marie
Scholl Apparatebau GmbH & Co. KG
Zinhainer Weg 4
D–56470 Bad Marienberg/Germany
Phone
+0049 (0) 2661 – 9868-10
Fax
+0049 (0) 2661 – 9868-38 (Service)
Internet
www.scholl-gastro.de
E-mail
info@scholl-gastro.de
BA
Last revised 01-2018
Separately heated basins
Model-No.
Art. No.
3112/2/ZAÜ
G 1211
3113/3/ZAÜ
G 1311
3114/4/ZAÜ
G 2411
3212/2/ZAÜ
G 2211
3213/3/ZAÜ
G 2311
3214/4/ZAÜ
G 2511
Size 32 Bain-Marie
Page 1 of 47
Januar 15, 2018
Rev. 4

Advertisement

Table of Contents
loading

Summary of Contents for Scholl 3111/ZAU

  • Page 1 G 2311 3214/ZAÜ G 2501 3214/4/ZAÜ G 2511 Size 31 Bain-Marie Size 32 Bain-Marie Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D–56470 Bad Marienberg/Germany Phone +0049 (0) 2661 – 9868-10 +0049 (0) 2661 – 9868-38 (Service) Internet www.scholl-gastro.de E-mail info@scholl-gastro.de...
  • Page 2: Table Of Contents

    GBA G 1101 4 E ABLE OF CONTENTS Table of contents ............................... 2 Preface ................................5 Conventions ............................... 6 Pictograms – General safety notes ....................6 Pictograms – Warning notes ......................7 Pictograms – Important notes ......................8 Product information ..........................9 Execution of size 31 Bain-Marie ZAÜ...
  • Page 3 GBA G 1101 4 E Troubleshooting ............................18 Possible malfunctions ........................19 Technical data............................20 Technical data size 31 Bain-Marie ZAÜ, continuously heated ............20 Technical data size 31 Bain-Marie ZAÜ, separately heated ............20 Technical data size 32 Bain-Marie ZAÜ, continuously heated ............21 Technical data size 32 Bain-Marie ZAÜ, separately heated ............
  • Page 4 GBA G 1101 4 E Circuit diagrams ..........................38 10.1 Circuit diagrams Bain-Marie ZAÜ, continuously heated ..............38 10.1.1 Circuit diagram Bain-Marie ZAÜ, continuously heated, GN 1 x 1/1 ........38 10.1.2 Circuit diagram Bain-Marie ZAÜ, continuously heated, GN 2 x 1/1 ........39 10.1.3 Circuit diagram Bain-Marie ZAÜ, continuously heated, GN 3 x 1/1 ........
  • Page 5: Preface

    REFACE Congratulations! In purchasing this new SCHOLL appliance you have chosen a product which meets highest technical stand- ards while providing outstanding convenience in practical use. This appliance has been designed with minimal energy consumption in mind. Used responsibly, it will serve you well in an ecologically sound manner.
  • Page 6: Conventions

    GBA G 1101 4 E ONVENTIONS – G ICTOGRAMS ENERAL SAFETY NOTES Be sure to observe these Instructions for Use as well as the safety notes to prevent injuries or damage to health or property. Do not alter or modify this appliance. Never use a defective appliance.
  • Page 7: Pictograms - Warning Notes

    GBA G 1101 4 E – W ICTOGRAMS ARNING NOTES Cleaning must only be performed by qualified persons who have read and under- stood these Instructions for Use and are familiar with applicable hygiene rules. En- sure that care is exercised during cleaning of the unit. For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water which contains a small amount of dishwashing detergent.
  • Page 8: Pictograms - Important Notes

    GBA G 1101 4 E – I ICTOGRAMS MPORTANT NOTES DANGER indicates an immediately threatening hazard. Failure to observe this warning notice will result in severe physical injury or death. WARNING indicates a potentially dangerous situation. Failure to observe this warning notice may result in severe physical injury or death.
  • Page 9: Product Information

    GBA G 1101 4 E RODUCT INFORMATION Bain-Maries are electrically heated warm retaining basins. Bain-Maries are operated with water and are used for keeping warm preheated food at output temperature. Bain-Maries are feeded from above with GN-insets in accordance with DIN EN 631-1. 31 B ZAÜ...
  • Page 10: Information Regarding Compliance With Standards, Laws And Directives

    GBA G 1101 4 E NFORMATION REGARDING COMPLIANCE WITH STANDARDS LAWS AND DIRECTIVES This appliance conforms to the following: Standards, laws, directives 2014/35/EU Low Voltage Directive 2014/30/EU EMC Directive AFETY This appliance conforms to accepted technical rules and relevant safety codes. However, proper use of the appliance is a prerequisite for effectively preventing damage or accidents.
  • Page 11: Packing, Transport, Intermediate Storage, Scope Of Delivery

    GBA G 1101 4 E ACKING TRANSPORT INTERMEDIATE STORAGE SCOPE OF DELIVERY ACKING The type of packing employed will depend, to a large extent, on the adopted shipping mode and route. Except where otherwise agreed by contract, packing will conform to the "HPE Packing Guideline" defined by the German Federal Association of the Wooden Materials, Pallets and Export Packing Industry and by the German Engineering Federation.
  • Page 12: Installation

    GBA G 1101 4 E NSTALLATION ZAÜ NSTALLATION ARIE AND THERMOSTAT BUILT IN CASING Practice:  Prepare cut-out for Bain-Marie in on site worktop.  Prepare cut-out for thermostat built-in casing in on site counter top.  Remove the toggle from the thermostat built-in casing and screw off the front cover. ...
  • Page 13: Electrical Installation

    GBA G 1101 4 E LECTRICAL INSTALLATION The appliance may only be installed by a qualified electrician whilst taking into account the applicable regulations! Connect this appliance to suitably earthed mains outlets only. Ensure that your mains power supply conforms to the data stated on the nameplate of the appliance. Failure to observe this warning may result in a fire hazard or electrical shock! Before putting the appliance into service, observe the following: ...
  • Page 14: Operation

    GBA G 1101 4 E PERATION For each basin, the Bain-Marie has a dedicated thermostat and a dedicated indicator lamp. The thermostat switches the Bain-Marie on and off and sets the temperature: Thermostat off Position "0" (number "0" is below the mark) Thermostat on Position "1"...
  • Page 15: Unintended Use Bain-Marie Zaü

    GBA G 1101 4 E ZAÜ NINTENDED USE ARIE Please observe strictly:  Bain-Maries are for defrosting/warming up of deep-frozen/cooled food.  Bain-Maries are for cooking food.  Bain-Marie must be used without water!  Bain-Marie must be used with any liquids other than water! Page 15 of 47 Januar 15, 2018 Last revised 01-2018...
  • Page 16: Maintenance

    GBA G 1101 4 E AINTENANCE AINTENANCE AND REPAIR Maintenance and repairs on the appliance must only be carried out by an author- ized professional observing applicable safety regulations. Improperly executed work will put your safety at risk. Before any cleaning, maintenance or repair work is carried out, the appliance must be disconnected from the mains and de-energized.
  • Page 17 GBA G 1101 4 E For light cleaning, wipe down the surface with a cloth or soft brush/sponge soaked in warm water containing a small amount of dishwashing detergent. Follow this up by wiping with clear water until no cleaning agent residue remains on the surface, as the latter might cause discoloration or stains.
  • Page 18: Troubleshooting

    GBA G 1101 4 E ROUBLESHOOTING Repairs must be carried out by an authorized specialist in compliance with applica- ble safety codes and regulations. Improperly executed work will put your safety at risk! Note that some work must only be carried out by an electrical specialist. According to DIN EN 60204-1: 2011-01, specialists are „persons who by reason of their relevant training and experience are capable of recognizing risks and avoiding potential hazards."...
  • Page 19: Possible Malfunctions

    GBA G 1101 4 E OSSIBLE MALFUNCTIONS Malfunction Cause Remedy Bain-Marie does not heat Overheating protection has Let the device cool off until the switched off the Bain-Marie. overheating protection that is Operating error: on the adhesive foil heating Bain-Marie was used drily with- switches off again on its own.
  • Page 20: Technical Data

    GBA G 1101 4 E ECHNICAL DATA 31 B ZAÜ, ECHNICAL DATA SIZE ARIE CONTINUOUSLY HEATED Basin rim folded 15 mm down all around Basin: continuously heated Depth: 630 mm Height: 280 mm Filling: on site Model-No. Length GN-insets Voltage Power Art.
  • Page 21: Technical Data Size 32 Bain-Marie Zaü, Continuously Heated

    GBA G 1101 4 E 32 B ZAÜ, ECHNICAL DATA SIZE ARIE CONTINUOUSLY HEATED Bain-Marie basin for flush fitting Basin: continuously heated Depth: 630 mm Height: 280 mm Filling: on site Model-No. Length GN-insets Voltage Power Art. No. 3211/ZAÜ 425 mm 1 x 1/1-200 230 V 1,0 kW...
  • Page 22: Dimensioned Drawings

    GBA G 1101 4 E IMENSIONED DRAWINGS 31 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE CONTINUOUSLY HEATED 9.1.1 D 31 B ZAÜ, , GN 1 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3111/ZAÜ G 1101 Supply 1/2” with ball valve Drain 3/4"...
  • Page 23: Dimensioned Drawing Size 31 Bain-Marie Zaü, Continuously Heated, Gn 2 X 1/1

    GBA G 1101 4 E 9.1.2 D 31 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3112/ZAÜ G 1201 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 23 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 24: Dimensioned Drawing Size 31 Bain-Marie Zaü, Continuously Heated, Gn 3 X 1/1

    GBA G 1101 4 E 9.1.3 D 31 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3113/ZAÜ G 1301 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 24 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 25: Dimensioned Drawing Size 31 Bain-Marie Zaü, Continuously Heated, Gn 4 X 1/1

    GBA G 1101 4 E 9.1.4 D 31 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3114/ZAÜ G 2401 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 25 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 26: Dimensioned Drawings Size 31 Bain-Marie Zaü, Separately Heated

    GBA G 1101 4 E 31 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE SEPARATELY HEATED 9.2.1 D 31 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3112/2/ZAÜ G 1211 Supply 1/2” with ball valve Drain 3/4"...
  • Page 27: Dimensioned Drawing Size 31 Bain-Marie Zaü, Separately Heated, Gn 3 X 1/1

    GBA G 1101 4 E 9.2.2 D 31 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3113/3/ZAÜ G 1311 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 27 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 28: Dimensioned Drawing Size 31 Bain-Marie Zaü, Separately Heated, Gn 4 X 1/1

    GBA G 1101 4 E 9.2.3 D 31 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3114/4/ZAÜ G 2411 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 28 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 29: Dimensioned Drawings Size 32 Bain-Marie Zaü, Continuously Heated

    GBA G 1101 4 E 32 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE CONTINUOUSLY HEATED 9.3.1 D 32 B ZAÜ, , GN 1 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3211/ZAÜ G 2101 Supply 1/2” with ball valve Drain 3/4"...
  • Page 30: Dimensioned Drawing Size 32 Bain-Marie Zaü, Continuously Heated, Gn 2 X 1/1

    GBA G 1101 4 E 9.3.2 D 32 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3212/ZAÜ G 2201 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 30 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 31: Dimensioned Drawing Size 32 Bain-Marie Zaü, Continuously Heated, Gn 3 X 1/1

    GBA G 1101 4 E 9.3.3 D 32 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3213/ZAÜ G 2301 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 31 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 32: Dimensioned Drawing Size 32 Bain-Marie Zaü, Continuously Heated, Gn 4 X 1/1

    GBA G 1101 4 E 9.3.4 D 32 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE CONTINUOUSLY HEATED Model No. Art. No. 3214/ZAÜ G 2501 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 32 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 33: Dimensioned Drawings Size 32 Bain-Marie Zaü, Separately Heated

    GBA G 1101 4 E 32 B ZAÜ, IMENSIONED DRAWINGS SIZE ARIE SEPARATELY HEATED 9.4.1 D 32 B ZAÜ, , GN 2 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3212/2/ZAÜ G 2211 Supply 1/2” with ball valve Drain 3/4"...
  • Page 34: Dimensioned Drawing Size 32 Bain-Marie Zaü, Separately Heated, Gn 3 X 1/1

    GBA G 1101 4 E 9.4.2 D 32 B ZAÜ, , GN 3 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3213/3/ZAÜ G 2311 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 34 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 35: Dimensioned Drawing Size 32 Bain-Marie Zaü, Separately Heated, Gn 4 X 1/1

    GBA G 1101 4 E 9.4.3 D 32 B ZAÜ, , GN 4 IMENSIONED DRAWING SIZE ARIE SEPARATELY HEATED Model No. Art. No. 3214/4/ZAÜ G 2511 Supply 1/2” with ball valve Drain 3/4" with ball valve Page 35 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 36: Cut-Out Dimensions Size 31 And 32 Bain-Marie Zaü

    GBA G 1101 4 E 32 B ZAÜ OUT DIMENSIONS SIZE ARIE Model-No. Length GN-insets Art. No. Cut-out size 3111/ZAÜ G 1101 425 mm 1 x 1/1-200 400 mm x 605 mm 3211/ZAÜ G 2101 3112/ZAÜ G 1201 3112/2/ZAÜ G 1211 770 mm 2 x 1/1-200 745 mm x 605 mm...
  • Page 37: Thermostat With Built-In Casing

    GBA G 1101 4 E HERMOSTAT WITH BUILT IN CASING Built-in casing with 2 cable screw connections Built-in casing with 1 cable screw connection for continuously heated basins for separately heated basins Cut-out size: 55 mm x 120 mm Installation depth: approx.
  • Page 38: Circuit Diagrams

    GBA G 1101 4 E IRCUIT DIAGRAMS 10.1 C ZAÜ, IRCUIT DIAGRAMS ARIE CONTINUOUSLY HEATED 10.1.1 C ZAÜ, , GN 1 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3111/ZAÜ G 1101 3211/ZAÜ G 2101 Key: Thermostat Heating incl. heat protection Indicator lamp Page 38 of 47 Januar 15, 2018...
  • Page 39: Circuit Diagram Bain-Marie Zaü, Continuously Heated, Gn 2 X 1/1

    GBA G 1101 4 E 10.1.2 C ZAÜ, , GN 2 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3112/ZAÜ G 1201 3212/ZAÜ G 2201 Key: Thermostat R1-R2 Heating incl. heat protection Indicator lamp Page 39 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 40: Circuit Diagram Bain-Marie Zaü, Continuously Heated, Gn 3 X 1/1

    GBA G 1101 4 E 10.1.3 C ZAÜ, , GN 3 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3113/ZAÜ G 1301 3213/ZAÜ G 2301 Key: Thermostat R1-R3 Heating incl. heat protection Indicator lamp Page 40 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 41: Circuit Diagram Bain-Marie Zaü, Continuously Heated, Gn 4 X 1/1

    GBA G 1101 4 E 10.1.4 C ZAÜ, , GN 4 IRCUIT DIAGRAM ARIE CONTINUOUSLY HEATED Model No. Art. No. 3114/ZAÜ G 2401 3214/ZAÜ G 2501 Key: Thermostat R1-R4 Heating incl. heat protection Indicator lamp Page 41 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 42: Circuit Diagrams Bain-Marie Zaü, Separately Heated

    GBA G 1101 4 E 10.2 C ZAÜ, IRCUIT DIAGRAMS ARIE SEPARATELY HEATED 10.2.1 C ZAÜ, , GN 2 IRCUIT DIAGRAM ARIE SEPARATELY HEATED Model No. Art. No. 3112/2/ZAÜ G 1211 3212/2/ZAÜ G 2211 Key: S1-S2 Thermostat R1-R2 Heating incl. heat protection H1-H2 Indicator lamp Page 42 of 47 Januar 15, 2018...
  • Page 43: Circuit Diagram Bain-Marie Zaü, Separately Heated, Gn 3 X 1/1

    GBA G 1101 4 E 10.2.2 C ZAÜ, , GN 3 IRCUIT DIAGRAM ARIE SEPARATELY HEATED Model No. Art. No. 3113/3/ZAÜ G 1311 3213/3/ZAÜ G 2311 Key: S1-S3 Thermostat R1-R3 Heating incl. heat protection H1-H3 Indicator lamp Page 43 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 44: Circuit Diagram Bain-Marie Zaü, Separately Heated, Gn 4 X 1/1

    GBA G 1101 4 E 10.2.3 C ZAÜ, , GN 4 IRCUIT DIAGRAM ARIE SEPARATELY HEATED Model No. Art. No. 3114/4/ZAÜ G 2411 3214/4/ZAÜ G 2511 Key: S1-S4 Thermostat R1-R4 Heating incl. heat protection H1-H4 Indicator lamp Page 44 of 47 Januar 15, 2018 Last revised 01-2018 Rev.
  • Page 45: Disposal And Environmental Notes

    GBA G 1101 4 E ISPOSAL AND NVIRONMENTAL OTES The appliance has been packed before shipping to protect it against damage in transit. After unpacking, please dispose of packing materials in an environmentally sound manner. All packing materials are eco-compatible, 100% recyclable and marked with a sym- bol to that effect.
  • Page 46: Warranty And Service

    GBA G 1101 4 E ARRANTY AND SERVICE 12.1 W ARRANTY CONDITIONS The manufacturer accepts no liability or warranty in the following cases:  failure to observe notes and instructions given in the Instructions for Use;  use of the product in a manner not conforming to its intended use; ...
  • Page 47: Service Address

    7:00 a.m. till 4:00 p.m. Fridays from 7:00 a.m. till 12:15 p.m. Outside these office hours please communicate your requests per e-mail or telefax. Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D-56470 Bad Marienberg/Germany Phone 0049 (0)2661/9868-10...