Operation; Operation Temperature Controller - Scholl 2009 Instructions For Use Manual

Plate warmer
Table of Contents

Advertisement

GBA A 0201 1 E
5
O
PERATION
The plate warmer has a digital temperature controller. The temperature controller switches the plate
warmer on and off and sets the temperature
5.1
O
PERATION TEMPERATURE CONTROLLER
The plate warmer has a digital temperature controller and can be adjusted at temperatures of 30-85°C.
Key UP
Pressing this key you can increase the parameter or parameter value or scroll the parameter
list.
Key DOWN
Pressing this key you can decrease the parameter or parameter value or scroll the parameter
list. At alarm the buzzer function can be switched off with this key.
Key SET
While SET key is pressed, the setpoint is indicated.
In addition, the SET key is used for setting parameters
Key Standby
Switching the controller on or off.
If none of the keys is pressed, the display indicates the actual value of the temperature. Pressing the SET
key, the setpoint shows on the display.
If the setpoint is to be changed, the SET key is to be kept pressed while adjusting the setpoint with the keys
UP and DOWN.
Please note that the setpoint can only be changed within the set setpoint limits.
The LED 1 lights up when the temperature controller heats.
The set temperature (set value) will be stored even after switching off the temperature controller. The last
set temperature (set value) is active after switching on the temperature controller.
BA
Last revised 01-2018
Page 12 of 23
Januar 18, 2018
Rev. 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

20112012A 0201A 0302A 0402

Table of Contents