Page 1
C 6023 CKZ 990 C 6029 CK 990 RAL C 6024 CKZ 990 RAL C 6030 Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D–56470 Bad Marienberg/Germany +0049 (0) 2661 – 9868-10 Phone +0049 (0) 2661 – 9868-38 (Service) Internet www.scholl-gastro.de...
GBA C 6019 6 E ABLE OF CONTENTS Table of contents ............................... 2 Preface ................................4 General ..............................5 Information about the user manual ....................5 Liability and warranty........................5 Copyright ............................6 Declaration of conformity ........................ 6 Safety ................................. 7 General .............................
Page 3
GBA C 6019 6 E 5.2.2 Electrical connections ........................ 15 Operation ............................15 5.3.1 Control panel ..........................16 Cleaning and maintenance ........................17 Safety instructions for cleaning...................... 17 Cleaning............................17 Safety instructions for maintenance ....................18 Maintenance ..........................18 Possible malfunctions ..........................19 Disposal ..............................
REFACE Congratulations! In purchasing this new SCHOLL appliance you have chosen a product which meets highest technical stand- ards while providing outstanding convenience in practical use. This appliance has been designed with minimal energy consumption in mind. Used responsibly, it will serve you well in an ecologically sound manner.
GBA C 6019 6 E ENERAL NFORMATION ABOUT THE USER MANUAL This user manual describes the installation, operation and maintenance of the device and serves as an im- portant source of information and reference. The knowledge of all safety and handling instructions contained in the user manual creates the conditions for the safe and proper operation of this device.
GBA C 6019 6 E OPYRIGHT The user manual, including any text, drawings, images and other depictions, is protected by copyright. Re- production in any manner and form - including excerpts - as well as the utilization and/or communication of the content is forbidden without permission in writing from the manufacturer.
GBA C 6019 6 E AFETY This section provides an overview of all-important safety aspects. In addition, each chapter provides precise safety instructions for the prevention of dangers which are marked with symbols. Moreover, the pictograms, signs and labels found on the device are to be observed and kept in legible condition.
GBA C 6019 6 E NTENDED USE The reliability of the device is only guaranteed if used properly in accordance with the specifications in the user manual. Any technical interventions, assembly and maintenance are to be made by qualified service personnel. The "Cold Plate”...
GBA C 6019 6 E RANSPORT PACKAGING AND STORAGE RANSPORT INSPECTION The delivery must be checked immediately upon receipt for completeness and transport damage. In case of visible transport damage, do not accept the delivery, or only do so conditionally. The extent of the damage on the transport has to be marked on the documents / delivery note.
GBA C 6019 6 E ECHNICAL DATA ECHNICAL SPECIFICATIONS 4.1.1 B UILT IN COLD PLATE Built-in cold plate Model-No. CK 330 CK 330 RAL CK 660 CK 660 RAL CK 990 CK 990 RAL Art.-No. C 6019 C 6020 C 6021...
GBA C 6019 6 E 4.1.2 B UILT IN COLD PLATE FOR CENTRAL COOLING SYSTEM Built-in cold plate for central cooling system Model-No. CKZ 330 CKZ 330 RAL CKZ 660 CKZ 660 RAL CKZ 990 CKZ 990 RAL Art.-No. C 6025 C 6026 C 6027 C 6028...
GBA C 6019 6 E RODUCT DIAGRAM 4.2.1 B UILT IN COLD PLATE Figure size 1 x 1/1 GN 4.2.2 B UILT IN COLD PLATE FOR CENTRAL COOLING SYSTEM Figure size 1 x 1/1 GN Page 12 of 24 März 8, 2022 Last revised 03-2022 Rev.
GBA C 6019 6 E NSTALLATION AND OPERATION AFETY INFORMATION WARNING! Risk of electrocution! The device must be installed by qualified professionals. • Device may cause injuries due to improper installation! • Before installation, check the data of the local power grid with the technical specifications of the unit (see nameplate).
GBA C 6019 6 E NSTALLATION AND ELECTRIC CONNECTION 5.2.1 I NSTALLATION OF THE COLD PLATE ONLY VALID FOR INSTALLATION VARIANTS • Put your device on a level and safe surface which stands the weight of the device. • Prepare the cut-out of the table according to our installation drawings and check the cut-out. A silicone gap of 5 mm for wood and stainless-steel buffets all around the unit, and a gap of 7 mm for stone and Dekton is mandatory.
GBA C 6019 6 E 5.2.2 E LECTRICAL CONNECTIONS • The socket circuit must be secured according to the performance details. • Connect the controller to the circuit board. • Plug the Schuko plug into the socket. Printed circuit board only for the following devices: C 6019, C 6020, C 6021, C 6022, C 6023, C 6024 PERATION •...
GBA C 6019 6 E 5.3.1 C ONTROL PANEL The cold plate can be set and operated via the touch control panel mounted on the front. The four buttons are used for adjusting settings, quick choice between preset values, as well as parameterization. Only press the buttons using a finger or a Touchpen.
GBA C 6019 6 E LEANING AND MAINTENANCE AFETY INSTRUCTIONS FOR CLEANING • Before cleaning and before repairing, disconnect the device from the outlet (pull the plug!) and al- low it cool. • Do not use caustic cleaning agents and make sure that no water seeps into the device. •...
GBA C 6019 6 E AFETY INSTRUCTIONS FOR MAINTENANCE • Check the power cable for damage from time to time. Do not use the device if the cable is dam- aged. If the cable is damaged, it must be replaced by customer service or a qualified electrician to avoid risks.
GBA C 6019 6 E OSSIBLE MALFUNCTIONS Problem Cause Remedy • Power plug not plugged in • Pull out the plug and insert it properly correctly • Fuse of the power supply has • Check fuse, test unit on a dif- No function tripped ferent elec.
GBA C 6019 6 E ISPOSAL Old equipment Your old device must be disposed of at the end of its service life in accordance with local regulations. It is advisable to contact a specialised waste management company, or to contact the local disposal service in your community.
GBA C 6019 6 E NSTALLATION DRAWINGS Dimensioned drawings are available upon request. EMPERATURE CONTROLLER COLD PLATE Dimensions Cut-out size Page 21 of 24 März 8, 2022 Last revised 03-2022 Rev. 6...
GBA C 6019 6 E ARRANTY AND SERVICE 11.1 W ARRANTY CONDITIONS The manufacturer accepts no liability or warranty in the following cases: ➢ failure to observe notes and instructions given in the Instructions for Use; ➢ use of the product in a manner not conforming to its intended use; ➢...
7:00 a.m. till 4:00 p.m. Fridays from 7:00 a.m. till 12:15 p.m. Outside these office hours please communicate your requests per e-mail or telefax. Scholl Apparatebau GmbH & Co. KG Zinhainer Weg 4 D-56470 Bad Marienberg/Germany Phone 0049 (0)2661/9868-10...