EDITION 03/2012
OPERATING MANUAL
4.4.2
FUNCTIONS OF THE SPRAY GUN
When the spray gun is connected to the control unit
and the control unit is switched on, the pre-defi ned
recipe (R1, R2 or R3) is shown on the gun display (2) as
follows.
Recipe 1 -> ●❍❍❍❍ R1
Recipe 2 -> ●●●❍❍ R2
Recipe 3 -> ●●●●● R3
Recipe change R1 -> R2 -> R3 -> R1
Press the operating button (4) and hold the button
pressed of at least 2 seconds, then it is advanced by
1 recipe.
Display (2) -> ●●❍❍❍ = recipe values changed temporarily:
The stored recipe values of the previously selected recipe
number are re-loaded from memory by pressing the operating
button (4) for 2 seconds.
The trigger can be used to activate, one after the other, the
various functions of the spray gun.
Distance
Description
1
AirCoat air opens.
2
AirCoat air opened and electrostatic (HV)
activated.
-> Display (2) for „spray current" on the spray
gun ●❍❍❍❍ to ●●●●● activated.
3
AirCoat air opened and electrostatic (HV)
activated and material valve opened.
4
Max way of trigger.
•
An increase in the tension needed to pull the trigger back
will be felt at the position where the material valve opens.
•
For spraying without high-voltage, the high-voltage can
be switched off using the operating button (4). Press the
operating button (4) briefl y: High-voltage is switched off.
The standby display (3) illuminates.
•
In the event of a malfunction the spray gun switches to
„standby" operating mode and the display (3) illuminates.
•
The width of the spray jet can be adjusted using the air
adjustment (16) (only for fl at-jet method).
PART NUMBER DOC 2319150
2
3
4
1
2
3
4
E
16
GM
5000EAC.
R2
B_03182
R2
B_03262
19