Positioning Of The Unit; Earthing - WAGNER GM5000 Operating Manual

3-in-1 electrostatic, aircoat & airless system
Table of Contents

Advertisement

EDITION 03/2012
OPERATING MANUAL
5.2

POSITIONING OF THE UNIT

Incorrect installation of the unit!
Risk of explosion and equipment damage
SIHI_0143_GB
All sealed elements in the control device must be available and undamaged. During
operation, all electric connections in the control unit and relevant plug connectors or
shut-off devices have to be tightly sealed. When under voltage, neither plug connectors
nor any shut-off devices may be separated or opened.
Sparking by separation and joining of live construction units!
Danger of explosion by electrical sparks
SIHI_0144_GB
5.3

EARTHING

Perfect earthing of all system components (work pieces, conveyor, paint supply system,
control unit, spray booth or spraying stand, see illustration) is a prerequisite for optimum
coating effi ciency and safety.
Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic sparks or flames
SIHI_0027_GB
PART NUMBER DOC 2318724
Place the unit outside the spray booth/zone.
Place the unit, if possible, outside the explosion zone
(Positioning in explosion zone 2 is enables).
Protect the unit from extreme temperature and moisture
changes.
Protect the unit against dirt.
Lay and fix the connecting cable correctly.
WARNING
Disconnect connectors not under tension.
Fuse holders under tension do not open.
Remove the service plug cover not under tension.
Earth all unit components.
Earth the workpieces being painted.
DANGER
WARNING
VM 500
18