8.2
Storage
8.2.1
Ambient conditions for long-term storage
Based on DIN EN 60721-3-1 (for long-term storage)
Table 8-6
Climatic ambient conditions
Lower air temperature limit:
Upper air temperature limit:
Lower relative humidity limit:
Upper relative humidity limit:
Rate of temperature fluctuations:
Condensation:
Formation of ice:
Long-term storage:
Storage is only permissible in locations that are fully protected against the weather
(in halls or rooms).
Table 8-7
Biological ambient conditions
Long-term storage:
Table 8-8
Chemical ambient conditions
Long-term storage:
Table 8-9
Mechanically active ambient conditions
Long-term storage:
Table 8-10
Mechanical ambient conditions
Long-term storage:
1FW6 Built-in torque motors
Configuration Manual, 09/2022, A5E52220645B AA
- 5° C (deviates from 3K3)
+ 40° C
5 %
85 %
Max. 0.5 K/min
Not permissible
Not permissible
Class 1K3 and class 1Z1 have a different upper relative humidity
Class 1B1
Class 1C1
Class 1S2
Class 1M2
Preparation for use
8.2 Storage
423