Technical Data: 5500 Manifolds - Pepperl+Fuchs Bebco EPS 5500 Series User Manual

Type z and ex pzc purge and pressurization system
Table of Contents

Advertisement

5500 S
M
 P
erieS
anual
5500 manifolds include the solenoid and manual needle valve, as well as the following:
3/8 inch compression ferrule fittings for inlet and outlet protective gas source
z
3/8 inch compression ferrule bulkhead fitting that attaches to enclosure—for protective gas to
z
inside enclosure
3/8 inch poly tubing (2 m length)
z
Inserts for poly tubing to ferrule fitting connection. If stainless steel tubing is used, inserts are not
z
required.
Hex key for pressurization valve included with 5500-MAN-CDUL version
z
Mounting hardware: screws, nuts, and sealing washers
z
Note
When ordering, note the supply voltage of the 5500 control unit. Order the manifold
valves accordingly. Voltages are 24 V DC, 120 V AC, and 220 V AC. 5500 MAN-CDUL
manifold valves are only available with 60 Hz operation.
2.5.1

Technical Data: 5500 Manifolds

Property
General specifications
Operation mode
Series
Hazardous environment
Supply
Rated power equipment
24 V DC
120 V AC
230 V AC
Rated power equipment
24 V DC
120 V AC
230 V AC
Rated power equipment
24 V DC
120 V AC
230 V AC
Voltage tolerance
32
d
roducT
eScriPTion
Value
Compressed air or inert gas, 40 µm filter, free from oil
5500
gas or dust
5500-MAN-CDUL
5.6 W
7.2 VA, 60 Hz
7.2 VA, 60 Hz
5500-MAN-CD01
4.6 W
6.8 VA, 60 Hz
6.8 VA, 60 HZ
5500-MAN-EX01
2.6 W
3.1 VA, 50 ... 60 Hz
3.0 VA, 50 ... 60 Hz
± 10 %