2.4. EPV-5500 Vents

EPV-5500 vents work with the 5500 control unit and manifold to provide a functional,
certifiable purge and pressurization system for enclosures. As required by all
pressurized enclosure systems, the EPV-5500 vent functions as a pressure relief
device and allows the purge gas to exit the enclosure, yet provides a seal when the
enclosure is pressurized and operating. The vent also has a spark arrestor, which is
required for hazardous areas.
EPV-5500 Components
EPV-5500 vent with spark arrestor
z
Sealing washer and nut for internal or external mounting
z
Hex key for removing, attaching, and rotating the vent cap
z
2.4.1

Technical Data: EPV-5500 Vents

Item
Pneumatic parameters
Protective gas supply
Maximum pressure
Purge flow rate
Flow rate for leakage compensation
Breaking pressure
24
d
roducT
eScriPTion
Value
Compressed air or inert gas, 40 µm filter, free from oil
Depends on the integrity of the enclosure (strength)
See graphs
EPV-....-01:
approx. 21 scfh (593 l/hr) at 0.63 mbar (0.25 in wc)
approx. 58 scfh (1640 l/hr) at 1.9 mbar (0.75 in wc)
EPV-....-02:
approx. 14 scfh (395 l/hr) at 0.63 mbar (0.25 in wc)
approx. 34 scfh (961 l/hr) at 1.9 mbar (0.75 in wc)
EPV-....-03:
approx. 9.2 scfh (260 l/hr) at 0.63 mbar (0.25 in wc)
approx. 22 scfh (622 l/hr) at 1.9 mbar (0.75 in wc)
EPV-....-01: 2.0 mbar (0.8 in wc)
EPV-....-02: 3.5 mbar (1.4 in wc)
EPV-....-03: 3.8 mbar (1.5 in wc)