2.3.1 Technical Data: Control Unit

Item
Supply
Rated voltage Ur
Power consumption
Electrical Specifications
Fuse Rating
Value
100 ... 240 V AC, 0.05 A, 50 ... 60 Hz
20 ... 30 V DC, 0.2 A
Overvoltage category II
100 ... 240 V AC - 2.3 VA (without digital valve)
20 ... 30 V DC - 2.5 W (without digital valve)
F2:
AC: 2 A slow blow, 5 x 20 mm
DC: 3.15 A slow blow, 5 x 20 mm
F1:
AC: 0.08 A (max) slow blow, 5 x 20 mm
DC: 0.5 A (max) slow blow, 5 x 20 mm
Fuse must be UL Recognized under JDYX2/8