This section instructs you how to service each component inside the cooling unit.
I. Component Checking

1) Compressor

The compressor acts as a pump, forcing refrigerant through the sealed system.
A. Resistance
1. Unplug WINEMATE cooling unit or disconnect power.
2. Remove the terminal cover from the compressor.
3. Remove the start relay and overload protector from the compressor. If
wiring is removed from the start relay and/or overload protector, carefully
label each wire according to its proper location.
4. Set the ohmmeter scale to the lowest setting.
3.

Servicing and Diagnosis

Figure 3-1
- 13 -