Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 15 OR 20 AMPCIRCUIT IS HIGHLY RECOMMENDED. - 1 -...
Feature Description • HZD cooling unit is designed and used to provide a stable temperature ° between 50~65 F for suitable space at a normal environment. • The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid. •...
Page 5
• See the voltage, frequency and current from the label on the back or side of the cooling unit. The dimension and capacity are specified as follows: COOLING BOTTLE CAPACITY, DIMENSIONS IN. WEIGHT CAPACITY MODEL ELECTRICAL WXHXD (lb) ° ° F/75 °...
Installation Instruction Select a place to mount the unit where the exhaust airflow is unobstructed for a minimum of 6 inch. The area into which the unit exhausts must be well ventilated. If it is not, heat exhausted by the unit will build up and the unit will not operate °...
Page 10
Fig. 2.7 CABINET GRILLE 2. VINO3500-8500HZD THROUGH WALL INSTALLATION 1. Cut a rectangular opening at the wine room wall as illustrated. The dimensions of the opening shall be 1/4” larger than the width and height of the unit. 2. If top exhaust, cut another rectangular opening at the top of the cabinet to the length and width of the top exhaust.
Page 11
Fig. 2.8 THROUGH WALL INSTALLATION Fig. 2.9 TOP EXHAUST GASKET - 10 -...
Page 12
3. Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature.
Page 14
2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as soon as the temperature returns to normal value.
Page 15
2. The value of the set point will be displayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the keys arrows within 10s. 4. To memorize the new set point value, push the SET key again or wait 10s. 4) Humidity Adjustment The parameter Fon is used to adjust the humidity in the wine cabinet.
Page 16
7) Manual Defrost Push the DEF key for more than 2 seconds and a manual defrost will start. - 15 -...
Care Guide 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Coil is on the ambient air intake side of the cooling unit. • Unplug the unit or disconnect power. •...
Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not a. Power cord unplugged a. Check for power cord plug b.
Page 19
6. “HA” alarm a. Improper room insulation & seal a. Check for insulation, gasket and door opening blinking and b. Room too large b. Check for excessive size beeping, c. Ambient temperature too high c. Check for installation location temperature d.
Page 20
Refrigerant low or leaking Check current sealed system leakage g. Capillary tube blockage g. Check for low side pressure a. High humidity a. Use drain line 11.Water leak b. Air leak in wine cellar b. Check for any air leak c.
Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 22 -...
BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
Page 25
VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.