Cooling Unit
r
n
a
t
i
o
n
a
l
C
o
e
r
n
a
t
i
o
n
a
l
C
o
o
t
e
m
p
.
c
o
m
o
t
e
m
p
.
c
o
m
e
m
a
t
e
.
c
o
m
e
m
a
t
e
.
c
o
m
r
p
.
r
p
.

Advertisement

Table of Contents
loading

  Summary of Contents for Vinotemp WINE-MATE VINO1500HZD

  • Page 1 Cooling Unit WINE-MATE Use & Care Manual VINO1500HZD VINO2500HZD VINO3500HZD VINO4500HZD VINO6500HZD VINO8500HZD...
  • Page 2: Important Safety Information

    Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 OR 30 AMPCIRCUIT IS REQUIRED (1500-4500HZD OR 6500-8500HZD). - 1 -...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Features & Specifications.…………………….……………..3 Installation Instruction………………………………………..5 Temperature Control & Humidity Adjustment...………..13 Care Guide…………………………………………………….16 Troubleshooting……………………………………………..17 Wiring Diagram……………………………………….………20 Customer Support……………………………………………21 Warranty……………………………………………………….22 - 2 -...
  • Page 4: Features & Specifications

    Features and Specifications • HZD cooling unit is designed and used to provide a stable temperature ° between 50~65 F for suitable space at a normal environment. • The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid. •...
  • Page 5 The dimension and capacity are specified as follows: CAPACITY cu ft MODEL VINO-1500HZD VINO-2500HZD VINO-3500HZD VINO-4500HZD VINO-6500HZD VINO-8500HZD NOTES: • See the voltage, frequency and current specified on the label at the cooling unit. • Capacity is determined under the cabinet and ambient temperatures of °...
  • Page 6: Installation Instruction

    Installation Instruction Select a place to mount the unit where the exhaust airflow is unobstructed for a minimum of 6 inch. The area into which the unit exhausts must be well ventilated. If it is not, heat exhausted by the unit will build up and the unit will not operate properly.
  • Page 7 • If top exhaust, place another gaskets along the top exhaust at the top of the cooling unit (see Fig.2.3). • Move the cooling unit towards the mounting sides and push to press the gaskets (see Fig 2.5). • Fasten the 2 brackets and use 7/16” wrench to tighten the two ¼” screws (see Fig 2.6).
  • Page 8 Fig. 2.2 GASKET Fig. 2.3 TOP EXHAUST GASKET - 7 -...
  • Page 9 Fig. 2.4 THREAD INSERT Fig. 2.5 COOLING UNIT - 8 -...
  • Page 10 Fig. 2.6 FASTENING BRACKET & SCREW - 9 -...
  • Page 11 Fig. 2.7 CABINET GRILLE 2. VINO3500-8500HZD THROUGH WALL INSTALLATION • Cut a rectangular opening at the wine room wall as illustrated. The dimensions of the opening shall be 1/4” larger than the width and height of the unit. • If top exhaust, cut another rectangular opening at the top of the cabinet to the length and width of the top exhaust.
  • Page 12 • Attach the molding to the wall not the unit. • Plug the unit into a properly grounded and dedicated outlet of adequate capacity. Fig. 2.8 THROUGH WALL INSTALLATION Fig. 2.9 TOP EXHAUST GASKET - 11 -...
  • Page 13 3. Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
  • Page 14: Temperature Control & Humidity Adjustment

    Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize the temperature for each new temperature setting operation 2.
  • Page 15 2.1 LED Functions MODE Flashing Flashing Flashing 3) Alarm Signals 3.1 Code Description MESSAGE CAUSE Temperature probe faulty High temperature alarm Low temperature alarm External alarm 3.2 Alarm Recovery Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation.
  • Page 16 5) Parameter Programming 1. Press the SET + keys for 3 sec until the “°C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + displayed, then release the keys. The first parameter Hy will be displayed. 3.
  • Page 17: Care Guide

    1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Coil is on the ambient air intake side of the cooling unit. • Unplug the unit or disconnect power. •...
  • Page 18: Troubleshooting

    This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Complaint Possible Causes a. Power cord unplugged 1. Unit not b. No power to unit running c. Setting temperature d.
  • Page 19 Failed components a. Improper room insulation & seal 5. Unit running too long b. Exhaust restricted c. Room too large d. Ambient temperature higher > ° e. Dirty Condenser a. Post-compressor 6. Fan motor mode running but b. Incorrect power supply compressor c.
  • Page 20 11. Evaporator a. Evaporator air flow restriction b. Not stopping due to air leak, high freezing up ambient setting c. Low ambient temperature d. Bad thermostat or sensor e. Moisture in the system f. Refrigerant low or leaking g. Capillary tube blockage a.
  • Page 21: Wiring Diagram

    Wiring Diagram Fig. 6.1 VINO1500-2500HZD Wiring Diagram Fig. 6.3 VINO3500-8500HZD Wiring Diagram - 20 -...
  • Page 22: Customer Support

    Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 21 -...
  • Page 23: Warranty

    BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
  • Page 24 VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.