Setup; Warnings And Precautions; Stand-Alone Setup; Dmx Connection - SHOWTEC ACT Profile 50 RGBAL User Manual

Hide thumbs Also See for ACT Profile 50 RGBAL:
Table of Contents

Advertisement

ACT Profile 50 RGBAL
5.

Setup

Warnings and Precautions

Attention
Connect all data cables before supplying power.
Disconnect power supply before connecting or disconnecting data cables.

Stand-alone Setup

When the ACT Profile 50 RGBAL is not connected to a controller or to other devices, it functions as a
stand-alone device. It can be operated manually via the control panel and the manual controls or via
an optional remote control.
For more information about the control modes, refer to 6.2. Control Modes on page 23.

DMX Connection

DMX-512 Protocol

You need a DMX serial data link to run light shows of one or more devices using a DMX-512 controller.
The ACT Profile 50 RGBAL has 3-pin DMX signal IN and OUT connectors.
The pin assignment is as follows: pin 1 (ground), pin 2 (-), pin 3 (+).
Devices on a serial data link must be daisy-chained in a single line. The number of devices that you can
control on one data link is limited by the combined number of the DMX channels of the connected
devices and the 512 channels available in one DMX universe.
To comply with the TIA-485 standard, no more than 32 devices should be connected on one data link.
In order to connect more than 32 devices on one data link, you must use a DMX optically isolated
splitter/booster, otherwise this may result in deterioration of the DMX signal.
Notes:
Maximum recommended DMX data link distance: 300 m
Maximum recommended number of devices on a DMX data link: 32 devices

DMX Cables

Shielded twisted-pair cables with 3-pin XLR connectors must be used for a reliable DMX connection.
You can purchase DMX cables directly from your Highlite International dealer or make your own cables.
If you use XLR audio cables for DMX data transmission, this may lead to signal degradation and unreliable
operation of the DMX network.
When you make your own DMX cables, make sure that you connect the pins and wires correctly as
shown in Fig. 24.
Product code: 34033
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

34033

Table of Contents