Ausschwingrotor 6-fach /
Swing out rotor 6-times
90°
max. Laufzyklen /
max. cycles 120 000
Kapazität / capacity
ml
Maße / dimensions  / A
mm²
Anzahl p. Rotor / number p. rotor
Filterkarten / filter cards
Drehzahl / speed
RPM
RZB / RCF
3)
Radius / radius
mm
sec
9 (97%)
9
sec
Temperatur / temperature
1)
°C
Probenerwärmung/Sample
K
2)
temp. rise
4446
Ausschwingrotor 6-fach /
Swing out rotor 6-times
90°
max. Laufzyklen /
max. cycles 120 000
Kapazität / capacity
ml
Maße / dimensions  / A
mm²
Anzahl p. Rotor / number p. rotor
Filterkarten / filter cards
Drehzahl / speed
RPM
RZB / RCF
3)
Radius / radius
mm
9 (97%)
sec
sec
9
Temperatur / temperature
1)
°C
Probenerwärmung/Sample
2)
K
temp. rise
1) Tiefste erreichbare Temperatur bei maximaler Drehzahl, 1 h
Laufzeit und 20°C Raumtemperatur (nur bei Kühlzentrifuge)
2)
Probenerwärmung bei maximaler Drehzahl und
1 Stunde Laufzeit (nur bei Zentrifuge ohne Kühlung)
3) Angaben des Röhrchenherstellers beachten.
4)
nicht mit Deckel 5053/5093 verschließbar
6)
Objektträger nur belastbar bis RZB 1100
12) Nach DIN EN 61010, Teil 2 – 020. Die Hinweise für Bio-Sicher-
heitssysteme in den Kapiteln "Sicherheitshinweise" und "Pflege und
Wartung" beachten.
1663
1664
1665
1
2
6,2 / 30
8,7 / 60
12,4 / 120
12
12
1675
1675
1675
4000
4000
4000
2290/3291
2290/3291
2290/3291
128 / 184
128 / 184
128 / 184
5051
+
5280
max. Laufzyklen / max. cycles: 50 000
max. Beladung / max. load: 500 g
1670
6)
2 x in 5280
1665
1666
1667
4
8
3 x 2
12,4 / 120
17,5 / 240
8,7 / 60
24
24
1692
1691
1694
4000
4000
4000
2290/3291
2290/3291
2290/3291
128 / 184
128 / 184
128 / 184
5051
+
5280
max. Laufzyklen / max. cycles: 50 000
max. Beladung / max. load: 500 g
1662
2 x in 5280
1666
1667
4
8
3 x 2
17,5 / 240
8,7 / 60
12
12
12
1676
1677
4000
4000
2290/3291
2290/3291
128 / 184
128 / 184
38
46
0
10
5053
SK 94.89
1668
Falcon
4 x 1
175
6,2 / 30
61 x 118
24
24
6
1693
---
4000
4000
2290/3291
3631
128 / 184
203
38
46
0
10
1) Lowest possible temperature during maximum speed, 1 h running
time and 20°C ambient temperature (only with cooling centrifuges)
2)
Sample temp. rise during maximum speed and 1 hour
running time (only with centrifuges without cooling)
3) Observe the tube manufacturer's instructions.
4)
not closeable with lid 5053/5093
6)
Object slide will not stand RCF values exceeding 1100
12) In conformity with DIN EN 61010, part 2 – 020. Observe the notes for
bio safety systems in chapters "Notes on safety" and "Maintenance
and servicing".
5053
1670
2 x in 5280
1668
1663
4 x 1
1
6,2 / 30
6,2 / 30
12
24
1678
1692
4000
4000
2290/3291
2290/3291
128 / 184
128 / 184
5092 + 5093
aerosoldicht / aerosol-proof 12)
max. Laufzyklen /
max. cycles: 30000
max. Beladung /
max. load: 500 g
5121
®
®
Falcon
----
4)
225
8
61 x 137
16 x 125
6
42
---
---
4000
4000
3631
3542
203
198
6)
1664
2
8,7 / 60
24
1692
4000
2290/3291
128 / 184
5120
-----
4,5 - 5
11 x 92
72
---
4000
3542
198
23 / 30