SECTION 4 - PROGRAMMING GUIDE

PROGRAMMING THE 65-218

The 65-218 is a matrix unit which in its basic form has 50 connections on its X axis and 4 on its Y axis and a bank
of 50 isolation switches on its X-axis. The 60-200 scalable chassis can be supplied with between one and six matrix
plugin modules which, in the case of the 65-218-111 and 65-218-121-CC plugin, are electrically isolated from each
other and are controlled by separate programming sub-units as shown in the graphic below:
Y1
Y2
Y3
Y4
CARD 6, SUB-UNIT 1 50x4 MATRIX
Slot 5
Matrix
65-218-111 Plugin (Bus=3 Device=5)
Y1
Y2
Y3
Y4
CARD 4, SUB-UNIT 1 50x4 MATRIX
Slot 3
Matrix
65-218-111 Plugin (Bus=3 Device=3)
Y1
Y2
Y3
Y4
CARD 2, SUB-UNIT 1 50x4 MATRIX
Slot 1
Matrix
65-218-111 Plugin (Bus=3 Device=1)
Figure 4-1. 65-218 Configured as a Hex 50x4 Matrix With Six 65-218-111 or 65-218-121-CC Plugin Modules
Page 4.2
CARD 6,
SUB-UNIT 2
X ISOLATION
X BUS LOOP-THRU
CARD 4,
SUB-UNIT 2
X ISOLATION
X BUS LOOP-THRU
CARD 2
SUB-UNIT 2
X ISOLATION
X BUS LOOP-THRU
LXI MODULAR HIGH VOLTAGE MATRIX 65-218
Y1
Y2
Y3
Y4
CARD 7, SUB-UNIT 1 50x4 MATRIX
Slot 6
Matrix
X BUS LOOP-THRU
65-218-111 Plugin (Bus=3 Device=6)
Y1
Y2
Y3
Y4
CARD 5, SUB-UNIT 1 50x4 MATRIX
Slot 4
Matrix
X BUS LOOP-THRU
65-218-111 Plugin (Bus=3 Device=4)
Y1
Y2
Y3
Y4
CARD 3, SUB-UNIT 1 50x4 MATRIX
Slot 2
Matrix
X BUS LOOP-THRU
65-218-111 Plugin (Bus=3 Device=2)