Specifications
Relay Type
The 65-218 is fitted with high quality electro-mechanical
relays. A spare relay is built onto the circuit boards to
allow easy maintenance with minimum downtime.
Matrix Switching Specification - Single Plugin Module
General:
Maximum Size:
Max Hot Switch Voltage:
Max Cold Switch Voltage
(65-218-101):
Max Cold Switch Voltage
(65-218-111):
Max Cold Switch Voltage
(65-218-121-CC):
Max Switch/Carry Current:
Max Switching Power:
Estimated Plugin Setting Time:
Initial Path Resistance - On:
Initial Path Resistance - Off:
Thermal Offset:
Crosspoint Closure Limit:
Expected Life (operations)
Very low power signal load:
Low power load (2 W):
Medium power load (30 W):
* For full voltage rating, signal sources to be switched
must be fully isolated from mains supply and safety earth.
Power Source
Universal AC mains supply, 90-120/200-240 V 50-60 Hz.
Power Inlet:
Power Rating:
Fuse Rating:
LAN Interface
1000Base-T Ethernet Interface with a standard RJ-45
connector mounted on the rear panel. Compliant to LXI
Standard 1.5
Provides 4 concurrent
connections between Y & X
or X & Y. Ability to expand
matrix size using loop-thru
connections
300x4 using 6 plugins in
a 65-200-002 chassis
220 VDC/250 VAC*
400 VDC* continuous
750 VDC* continuous
& higher voltage pulse
conditions, e.g. typically
1000 VDC for 1 s with low
duty cycle.
1000 VDC* continuous
2 A/2 A
60 W
<5 ms (per relay or relay
block operation) Note: This
figure may vary depending
upon user setup and
network load.
Plugin: <200 mΩ
>10
Ω
9
<4 µV
57 per plugin,
307 system level
>1x10
8
>1.5x10
(0.1 A, 20 VDC)
7
>5x10
(1 A, 30 VDC)
6
Male IEC connector
100 VA maximum
(F) 5 A 250 V
LXI MODULAR HIGH VOLTAGE MATRIX 65-218
SECTION 1 - TECHNICAL SPECIFICATION
LXI Modular High Voltage Matrix, 65-218
Matrix RF Specification - Single Plugin Module
Bandwidth (-3dB):
VSWR:
Crosstalk (typical):
Isolation (typical):
Mechanical Specification - Scalable Chassis
Chassis Dimensions:
Number of Plugins Supported: 6 (in 65-200-002 chassis)
Plugin Weight:
Plugin Connectors:
Trigger Connector:
Cooling:
Triggering
• 16x Software Configurable Bidirectional Open Collector
Triggers
• 1x Dedicated Software Reset Line
• 1x Dedicated Software Fault Line
• 1x Dedicated Interlock Line
Scan List Sequencing
Capable of storing 5000 predefined test sequences,
loaded from the host Controller to the LXI unit at process
initialization, with the ability to be triggered through software
or from any of the sixteen software configurable triggers.
For more information on the Pickering Sequence Manager,
please go to:
pickering-sequence-manager
(Measurement at front panel)
Plugin: 8.5 MHz
1.5:1 @ 1.98 MHz
-51 dB @ 10 kHz
-48 dB @ 100 kHz
-35 dB @ 1 MHz
-21 dB @ 5 MHz
-14 dB @ 10 MHz
-11 dB @ 12.5 MHz
-7 dB @ 25 MHz
71 dB @ 10 kHz
74 dB @ 100 kHz
62 dB @ 1 MHz
54 dB @ 5 MHz
49 dB @ 10 MHz
43 dB @ 12.5 MHz
30 dB @ 25 MHz
2 U rack mountable full
width, depth 500 mm.
0.8 Kg
1x 50-pin HV D-type for
X connections
1x 50-pin HV D-type for
X loop-thru connections
1x 9-pin HV D-type for Y/Y
loop-thru connections
25-pin male micro D-type
Front air intakes through
plugin module holes,
temperature controlled
speed adjustable fans.
pickeringtest.com