HDX and RTX setup:
**HDX/RTX systems can be configured with the Dakota Digital app for Apple and Android devices**
HDX and RTX Operations
HDX: With the ignition key already on, press and hold both switches to enter SETUP, release when instructed.
o
If using the external rocker switch, hold SW2 (II) while turning the ignition on.
o
Release the switch when SETUP is shown.
o
Left switch on display is SW1, and right switch on display is SW2
RTX: With the ignition off, press hold SW2 (II) while turning the ignition key on to enter SETUP
o
Release the switch when SETUP is shown.
BOTH: When holding for an option, release the button when the screens says "RELEASE"
BOTH: You may skip to whichever reading you'd like to configure below; they do not need to be done in order.
BOTH: After making a selection, tap a switch and select BACK to save and return to the main menu, then select
EXIT SETUP to return to normal operation.
BOTH: SWI (left) moves up ↑ the menu list, SWII (right) moves down ↓ the menu list
Obtaining RPM from the BIM-01-2-HLLY
Tap SWII (right) switch until TACH is selected. Press and hold SWII (right) switch to enter TACH menu.
Tap SWII (right) switch until INPUT is displayed. Press and hold SWII (right) switch to enter INPUT menu.
Tap SWII (right) switch until CYLINDER is displayed. Press and hold SWII (right) switch to select CYLINDER.
Tap SWI (left) switch until BIM is displayed. Press and hold SWII (right) switch to select BIM.
When INPUT is displayed again, tap until BACK is displayed, then hold the switch to exit.
Obtaining engine temperature from the BIM-01-2-HLLY
Tap SWII (right) switch until WATER is selected. Press and hold SWII (right) switch to enter WATER menu.
Tap SWII (right) switch until INPUT is displayed. Press and hold SWII (right) switch to enter INPUT menu.
Tap SWII (right) switch until BIM is displayed. Press and hold SWII (right) switch to select BIM.
When INPUT is displayed again, tap until BACK is displayed, then hold the switch to exit.
[5]
MAN #650832

Advertisement

loading