Making Connections; Realvision™ 3D Transducer Extension Cable; Mounting The Escutcheon Plate - Raymarine RV-100 Installation Instructions Manual

Transom realvision 3d sonar transducer
Table of Contents

Advertisement

approximately 0.5 cm further back towards the cable-end of the
connector.
Always use the supplied tool when attaching the split ring. The split ring
may become overstretched and break if you try to attach it without using
the tool. A spare split ring is supplied with the locking collar assembly,
in case of breakage.
4. Slide the O-ring (arrowed) over the end of the connector, and ensure
that it is seated squarely against the connector moulding, adjacent to
the split-ring.
5. Slide the locking collar towards the plug-end of the connector, rotating
the collar as necessary to ensure that the lugs on the locking collar
(labelled 'D' in the illustration) pass through the channels (labelled 'E')
in the split-ring.
The locking collar slides easily towards the plug-end of the connector,
before butting up against the split-ring moulding.
6. Grasp the body of the connector with one hand, then with the other hand,
pull the locking collar firmly towards the plug-end of the connector.
As you pull the locking collar, it clicks into place over the split-ring. The
locking collar stays in position on the connector, but rotates freely.

5.5 Making connections

Follow the steps below to connect the cable(s) to your product.
1. Ensure that the vessel's power supply is switched off.
2. Ensure that the device being connected to the unit has been installed in
accordance with the installation instructions supplied with that device.
3. Ensuring correct orientation, push the cable connector fully onto the
corresponding connector on the unit.
4. Turn the locking collar clockwise to secure the cable.
RealVision™ 3D transducer extension cable
For best performance, cable runs should be kept to a minimum. However, for
some installations it may be necessary to extend the transducer cable.
• RealVision™ transducer extension cable 3 m (9.8 ft) (part number A80475)
Mounting
• RealVision™ transducer extension cable 5 m (16.4 ft) (part number A80476)
• RealVision™ transducer extension cable 8 m (26.2 ft) (part number A80477)

5.6 Mounting the escutcheon plate

Your transducer is supplied with an escutcheon plate.
If you have chosen to route the transducer cable through the transom or
through a bulkhead, you can use the supplied escutcheon plate to cover the
hole required to accommodate the cable. The plate is designed to fit over a
hole up to 25 mm (1 inch) in diameter.
After you have threaded the transducer cable through the hole in the transom
or bulkhead, attach the escutcheon plate as shown, taking care that the cable
is not trapped between the escutcheon plate and the mounting surface.
Note:
To avoid possible damage to the transducer cable, use a file to round-off
the edges of the hole that the cable passes through.
25