5.3 Pulse Input Tab

5.3.1 Pulse Input Configuration

© Titan Enterprises Ltd 2023
®
Reed Relay:
Use when connecting a Reed relay flow
meter.
When ticked, this provides an additional extended filter in
which a logic high signal must be high for at least 560μs
before it is propagated; whereas a logic zero is propagated
immediately. This is intended for a circuit in which the reed
relay switches to ground with a pull-up resistor.
Detection: Pulse detection can be chosen for Rising edge,
Falling edge or Both edges of the input pulse.
"Both edge" detection measures both the rising and falling
edges.