  • Page 1 INSTRUCTION MANUAL Ultrasonic Flowmeter Range...
  • Page 2: Table Of Contents

    CONTENTS Page No General Installation Electrical Setup Technical Specification Revision No 2 - 1/5/2013...
  • Page 3: General

    500mbar plus two times the fluid vapour pressure. N = Nitrile • If there is any chance of air passing through the system mount the Atrato in a vertical E = EPDM pipe with the flow in an upward direction otherwise air can remain trapped in the meter S = Silicon and affect it’s performance.
  • Page 4: Electrical

    Electrical Setup The Atrato can be used entirely from a computer using the USB connection but this Before use, download and install Atrato software from memory stick or website. may not be acceptable in many situations where remote operation or further functions The Atrato low-flow ultrasonic flowmeter should be setup using the USB interface and a are required.
  • Page 5 – The display will show total flow only. BOth – The display can be cycled from rate to total using the left hand button on the Atrato or DEcREASE tOtAL fOR –vE fLOw: The meter will the left button in the “Real time window”. A not register negative flow unless this box is checked.
  • Page 6 Because of the potential for conflict should the PNP OutPut is selected the check box options are:- output be activated accidentally, Titan Enterprises Ltd recommend a resistor so that the Pulse Flow switch Reverse flow sink current cannot exceed 5mA.
  • Page 7 The large display reflects the OR:- If it is selected to “Output” and set to “Flow switch” the meter readings showing on the Atrato LCD Display, if Value column will show the transistor status either “low” or fitted and will mimic that display. The buttons either “high”...
  • Page 8 Pulse output selected Will turn off when rate below 2.7 Flow switch set to 3 L/Min 10% -ve flow. AtRAtO ADvAncED uSER tAB Will turn on when rate above 3.3 Flow switch set to 3 L/Min 10% +ve flow. Forward...
  • Page 9 PIn protection: This is for both the advanced and standard features. Accumulated total DP position. Accumulated total: Accessible and resettable from both the front panel and The chevron in the decimal point box calls a through the software. drop down selection showing the possible Minimum flow cut-off: This is to ensure that inaccurate low flow measurements are decimal point positions.
  • Page 10: Technical Specification

    Recorded flow Used flow Technical Specification Linearity ±1.0% of reading over flow range Recorded and numerical order Repeatability ±0.1% from 25% to 100% ±0.5% from 0 to 25% 2 3 0 0 2 3 2 is used Housing IP54 3 0 3 0 3 3 3 is used Temperature range...
  • Page 11 Taniya Infratech Co., Ltd. 965/234 Rangsit-Nakornnayok Rd., Prachathipat, Thunyaburi, Pathumthani 12130 Tel : 02-5498009 Fax : 02-5498010 www.taniyainfratech.com, www.thaiflowmeter.com Email : info@taniyainfratech.com tItAn EntERPRISES LtD. Coldharbour Business Park, Sherborne, Dorset DT9 4JW Phone: +44 (0)1935 812790 Fax: +44 (0)1935 812890 Email: sales@atratoflowmeters.com www.atratoflowmeters.com...