Parameter
Value
Flow
12.54
Input (Hz)
647.97
NPN Output
Off
237
237
Off
On
On
Off
PNP Output
Off
237
237
Off
On
On
Off
Analog
12.54
Current
12.54
12.54
Analog
3.22
Voltage
3.22
© Titan Enterprises Ltd 2023
®
Condition Description
Rate of Flow
Input Frequency
High
Not Used
No Power
Output Pulse
Active
Frequency (Hz)
High
Output Alarm State
Low
Output Alarm State
Low
Output Alarm State
High
Output Alarm State
Low
Not Used
Output Pulse
No Power
Frequency (Hz)
Output Pulse
Active
Frequency (Hz)
Low
Output Alarm State
High
Output Alarm State
High
Output Alarm State
Low
Output Alarm State
Analog Current
OK
output (4mA-20mA)
Analog Current
No Power
output (4mA-20mA)
Analog Current
Fault
output (4mA-20mA)
Analog Voltage
OK
output (0V-5V/10V)
Analog Voltage
No Power
output (0V-5V/10V)
www.flowmeters.co.uk
Additional Comments
Raw Flow Reading (without
viewing filter)
Frequency measure from
connected flowmeter
NOTE: Will Read +VDC if pull
up connected
No Alarm
+VDC
Alarm Triggered
0VDC
Invert Selected
No Alarm
0VDC
Invert Selected
Alarm Triggered
+VDC
NOTE: Will Read +VDC if pull
up connected
No +VDC. The PNP will not
work on USB power alone
No Alarm
0VDC
Alarm Triggered
+VDC
Invert Selected
No Alarm
0V
Invert Selected
Alarm Triggered
0VDC
No external power to meter
Wiring disconnected
No external power to meter
Pulsite®Link_Instruction_Manual_0823
25