3. Pipetting Head Specifications

Pipette Head
Number of
pipetting
channels
Pipetting
range/µL
Pipetting
accuracy
Pipetting
precision
MP9600-20PH
(20 µL)
96
1~20
1µL: ≤±12%
2µL: ≤±5%
10µL: ≤±1%
20µL: ≤±1%
1µL: ≤10%
2µL: ≤5%
10µL: ≤1%
20µL: ≤0.8%
MP9600-200PH
(200 µL)
96
5~200
5µL: ≤±5%
20µL: ≤±2%
100µL: ≤±1%
200µL: ≤±1%
5µL: ≤3.5%
20µL: ≤1.5%
100µL: ≤0.8%
200µL: ≤0.4%
3
MP9600-1000PH
(1000 µL)
96
100~1000
100µL: ≤±2.5%
500µL: ≤±1%
1000µL: ≤±1%
100µL: ≤1.25%
500µL: ≤0.4%
1000µL: ≤0.4%