5.04 Fault Indicator

At initial power up, two lights will temporarily illuminate for 2-3 seconds to show the version of software used.
To determine the first digit, count the function indicators left to right, 1 through 5. To determine the second digit count the pres-
sure indicators, reading from bottom to top, 0 through 7. In the example below the Temp indicator and 75 psi indicators are ON
indicating the version would be 2.3.
!
When the
"Fault" indicator is ON or blinking it will be accompanied by one of the pressure indicator lights depend-
ing on what the fault is. The following table explains each of those Faults.
NOTE!
Fault explanations are covered in the following tables.
Manual 0-5544
7
6
5
A
MAX
MIN
PSI
BAR
MAX
MAX
4
3
2
1
MIN
MIN
0
!
1 2 3 4
5
Pressure
Fault
Indicator
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
SERVICE
+
Art# A-13752
CUTMASTER 58