5.04 Fault Indicator

At initial power up, two lights will temporarily illu-
minate for 2-3 seconds to show the version of software
used.
To determine the first digit, count the function indicators
left to right, 1 through 5. To determine the second digit
count the pressure indicators, reading from bottom to
top, 0 through 7. In the example below the Temp indica-
tor and 75 psi indicators are on indicating the version
would be 2.3.
7
6
5
A
MIN
MAX
PSI
MAX
4
3
2
1
MIN
0
!
1 2 3 4
!
When the
"Fault" indicator is on or blinking it will
be accompanied by one of the pressure indicator
lights depending on what the Fault is. The following
table explains each of those Faults.
Pressure
Fault
Indicator
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE
Fault explantions are covered in the following
tables.