5
5.1 PE
PE
Protective Earth
PE
5.2 X2
X2
Motor Phases
Spring Cage Connector
Page 10/22
2
Use min. 4 mm
Tightening torque: 2 Nm
W:
Motor Phase W
V:
Motor Phase V
U:
Motor Phase U
PE:
Protective Earth
T+:
Temperature Sensor T+
T-:
Temperature Sensor T-
B+:
Motor Brake+
B-:
Motor Brake-
The coding and pin assignment of this connector has changed!
Please check carefully your cables!
Important Notices:
The Shield of the motor cable has to be mounted with a surface as large as possible
(low ohm, low impedance).
Use an EMC shield clamp mounting (LinMot MC10-EMV/14-D / Art. Nr. 0150-3631).
Max. cable length: 20 m (may be limited by motor)
Screw Terminals:
- Spring-cage connector
- Use 75 °C copper conductors only
- Conductor cross-section: 0.2 – 2.5 mm
- Stripping length 10 mm
Temperature sensors (thermistor) of the following types are supported:
- KTY 83/84
- PT1000
- PTC (digital)
Attention: An isolated thermistor is necessary!
Only use the following type of connector: LinMot MC10-B/m (Art. Nr. 0150-3605)