Locations And Clearances - Trane S8X1A026M2PSAB Installer's Manual

Upflow/downflow/horizontal gas-fired, 1–stage and 2–stage induced draft furnaces with high efficiency motor
Hide thumbs Also See for S8X1A026M2PSAB:
Table of Contents

Advertisement

F F u u r r n n a a c c e e I I n n s s t t a a l l l l a a t t i i o o n n G G u u i i d d e e l l i i n n e e s s
W W a a r r n n i i n n g g : : T T h h e e s s e e f f u u r r n n a a c c e e s s a a r r e e n n o o t t a a p p p p r r o o v v e e d d o o r r
i i n n t t e e n n d d e e d d f f o o r r i i n n s s t t a a l l l l a a t t i i o o n n i i n n m m a a n n u u f f a a c c t t u u r r e e d d ( ( m m o o b b i i l l e e ) )
h h o o u u s s i i n n g g , , t t r r a a i i l l e e r r s s , , o o r r r r e e c c r r e e a a t t i i o o n n a a l l v v e e h h i i c c l l e e s s . .

Locations and Clearances

The location of the Furnace is normally selected by the
architect, the builder, or the installer. However, before
Minimum clearance to combustible materials
3. Is there sufficient space for servicing the Furnace
and other equipment? A minimum of 24 inches
front accessibility to the Furnace must be provided.
Any access door or panel must permit removal of
the largest component.
4. Are there at least 3 inches of clearance between the
Furnace combustion air openings in the front panel
and any closed panel or door provided?
10
the Furnace is moved into place, be sure to consider
the following requirements:
1. Is the location selected as near the chimney or vent
and as centralized for heat distribution as practical?
2. Do all clearances between the Furnace and
enclosure equal or exceed the minimums stated in
Clearance Table below?
5. Are the ventilation and combustion air openings
large enough and will they remain unobstructed? If
outside air is used, are the openings set 12" above
the highest snow accumulation level?
6. Allow sufficient height in supply plenum above the
Furnace to provide for cooling coil installation, if
the cooling coil is not installed at the time of this
Furnace installation.
18-CE04D1-1D-EN