Section 4
Unpacking and Installation
Wall Mounting
(continued)
Cartridge / Membrane
Installation
4-6
Reverse Osmosis System
Warning Do not locate the Thermo Scientific RO system directly over
equipment that requires electrical service. Routine maintenance of this unit
may involve water spillage and subsequent electrical shock hazard if
improperly located.
Do not use in the presence of flammable or combustible materials; fire or
explosion may result. The device contains components which may ignite
such materials.
s
1. Locate the wall bracket packed separately from the unit.
2. Using the wall bracket as a template, locate and drill the mounting
holes in the wall. A minimum of four (customer-supplied) fasteners
will be required — two on the top and two on the bottom.
3. Attach the wall bracket to the wall using the customer-supplied
fasteners.
4. Remove the locking screws on each side of the wall bracket.
5. Pull the two locking slides on each side of the wall bracket out as far as
they will go.
Note Prior to installing the RO system on the wall or bench, it is
recommended that all cartridges and membranes are installed. See the
appropriate section of this manual for installation of cartridges and
membranes.
s
6. Hang the RO unit on the wall bracket by sliding the mounting pins
into the wall bracket slots.
7. Push the locking slides on each side of the wall bracket in as far as they
will go.
8. Replace the locking screws.
Your RO system has been shipped with a prefilter, carbon filter, MPS
cartridge and one membrane that you will install. To prepare your RO for
operation, disconnect the unit from the power supply if connected.