DIRECTIONS FOR USE
C A R B O N F I B E R A R M B O A R D (A C C E S S O R Y)
CAUTION
USE
This radiolucent device can be used with any flat support surface where ionizing radiation (x-ray) is
utilized for imaging. It can be used to support arms and feet.
DIRECTIONS
Unfold the Arm Board and slide the Base Section under the patient and the table pad. Position the
patient and the Support Section to suit the needs of the procedure. The weight of the patient will
hold the Arm Board in place.
Rotate the Support Section to the desired position. This section rotates up to 180º.
Prone Position at 135º
To remove the Arm Board, ask the patient to move their limb off the Support Section and lift their
body slightly. This will allow you to pull out the base section of the Arm Board.
Fold the Base and Support sections for storage.
T-R A I L C L A M P U S E (A C C E S S O R Y)*
CAUTION
1. The clamp must be installed only on an Oakworks
CFPM product with the groove on the underside of
the table.
2. Slide the clamp in the groove to the desired position
on the table top.
3. Ensure the lower part of the clamp is aligned with
and in the groove of the table top. Tighten the clamp
using the handle.
4. Attempt to slide the clamp. Ensure the clamp will not
move and is secured tightly to the tabletop.
5. The handle can be rotated without loosen up the
clamp. To move the handle out of your way, lift the
handle up and rotate towards the inside of the table, then release the handle to reengage. The
handle can then be used to tighten or loosen the clamp and slide to a different position on the
tabletop.
Note: The Integrated T-Rails are US standard size of .38" (1cm) thick by 1.13" (3cm) wide.
ExamTablesDirect.com
Shop tables & accessories at
Do not place undue weight or downward pressure on the Carbon Fiber Arm Board. It is a posi-
tioning device for the arms and should not be used as leverage to get on or off the table. Injury
can occur. DO NOT exceed 30 lbs. (14 kg.) of load on the Support Section. Injury can occur.
Supine Position at 180º
Recheck tightness of T-Rail Clamp in between procedures.
Ensure that the lower part of the clamp is in the tabletop groove under the table top.
Ensure the T-Rail Clamp is tight and can not move with pressure.
Support Section
Base Section