C O N T R A I N D I C A T I O N S The Oakworks Imaging and Pain Management Tables should not be used with Imaging systems hav- ing intensifier screens or film cassettes larger than 12 inches (30 cm) when an oblique angle of view is being used.
Page 5
Grounding reliability can only be achieved when this equipment is connected to an equivalent 3 prong receptacle marked “Hospital Only” or “Hospital Grade”. Oakworks medical tables are designed and built to provide many years of dependable service. Please fol- low local regulations and laws when disposing of the electrical components used in this table.
Page 6
1.50 mm. as measured at 100 kVp and a half value (HVL) of 3.6 mm.) • Oakworks Imaging and Pain Management Tables may be used for x-ray imaging where the x-ray generator is located below the tabletop and the image receptor is located above the table- top.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM100 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Electronic Lift Integrated Face Rest Tower with Crescent Face Pad Emergency Stop Locking Casters...
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM200 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Electronic Lift Integrated Face Rest Tower with Crescent Face Pad Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 9
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 200 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM300 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Electronic Lift Integrated Face Rest Tower with Crescent Face Pad Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 11
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 300 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM400 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 13
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 400 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM201 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Electronic Lift Integrated Face Rest Tower with Crescent Face Pad Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 15
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 201 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM301 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 17
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 301 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM302 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Electronic Lift Integrated Face Rest Tower with Crescent Face Pad Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 19
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 302 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPMB301 - Bariatric 24” x 80” Bariatric Carbon Fiber Top with Removable Table Top Pad Hand Rail Electronic Lift Tower Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS International Electric Configurations Motion 1 w/o pad Powered 26”-44”...
Page 21
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M B 301 B A R I A T R I C Do not apply excessive force to the foot control as it may damage the control.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFPM401 24” X 80” RECTANGULAR TOP Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad...
Page 23
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F P M 401 Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFLU401 - Lithotripsy/Urology Top Short Extension Carbon Fiber Top with Removable Table Top Pad Hand Rail (Under end) End Extension Emergency Stop T-rail (along each side) Locking Casters STANDARD SPECIFICATIONS Motion 1 w/o pad Powered 27”-45”...
Page 25
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F L U 401 L I T H O/U R O L O G Y Do not apply excessive force to the foot control as it may damage the control.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFUR301 - Urology Top Urology Carbon Fiber Top with Removable Table Top Pad Hand Rail (At end) T-rail Electronic Lift Tower Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad Powered 25”-43”...
Page 27
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F U R 301 U R O L O G Y Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) CFUR401 - Urology Top Urology Carbon Fiber Top with Removable Table Top Pad Hand Rail (At end) T-rail Electronic Lift Tower Emergency Stop Locking Casters STANDARD SPECIFICATIONS OPTIONS Motion 1 w/o pad Powered 28”-46”...
Page 29
PRODUCT DESCRIPTION (IMAGING AND PAIN MANAGEMENT FAMILY PRODUCTS) C O N T R O L O P E R A T I O N S - C F U R 401 U R O L O G Y Do not apply excessive force to the foot control as it may damage the control. CAUTION Do not use the hand or foot control if signs of wear or damage are visible as this can cause uninten- tional motion.
INSTALLATION The Imaging and Pain Management Tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (See Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
DIRECTIONS FOR USE B U B B L E L E V E L S Bubble levels are installed on the handle end of the table to aid the operator in determining the hori- zontal plane. A N G L E I N D I C A T O R Standard on CFPM 301, CFPM301B, CFPM401, CFLU401, CFUR401 and CFUR301 Tables.
DIRECTIONS FOR USE R E M O V E / R E P L A C E T H E T A B L E T O P P A D Make sure the top is not in motion when removing / replacing the table top pad. CAUTION Remove Table Pad by pulling flaps at the ends &...
DIRECTIONS FOR USE L O C K I N G C A S T E R S U S E All four casters should be locked at all times during use with a patient. LOCKING THE CASTERS: UN-LOCKING THE CASTERS: 1.
DIRECTIONS FOR USE W E I G H T C A P A C I T Y & P A T I E N T U S E The tabletop is rated at 500 lb. (227 kg) load evenly distributed. (Bariatric table is rated at 750 CAUTION lbs.
DIRECTIONS FOR USE L A T E R A L E X T E N S I O N S - L I T H O T R I P S Y/U R O L O G Y & U R O L O G Y T O P S CAUTION Do not sit on any extensions.
Ensure that the lower part of the clamp is in the tabletop groove under the table top. Ensure the T-Rail Clamp is tight and can not move with pressure. 1. The clamp must be installed only on an Oakworks CFPM product with the groove on the underside of the table.
Injury can occur. The Oakworks Fluoro Extender is radiolucent and offers extra width only where you need it for greater positioning accuracy with optimum imaging. The Fluoro Extender is inserted under the table top pad.
REFERENCE U S A B L E I M A G I N G A R E A - C F P M200, C F P M201, C F P M300, C F P M301, C F P M302, C F P M400, & C F P M401 I N T E G R A T E D H E A D R E S T T O P S O N L Y CENTERED FOR A-P VIEW: OBLIQUE 30°...
REFERENCE U S A B L E I M A G I N G A R E A - C F P M200, C F P M201, C F P M300, C F P M301, C F P M302, C F P M400, & C F P M401 R E C T A N G U L A R T O P S O N L Y CENTERED FOR A-P VIEW: OBLIQUE 30°...
REFERENCE U S A B L E I M A G I N G A R E A - C F L U401 CENTERED FOP A-P VIEW: CENTERED FOR A-P VIEW: 47.0" [119.38cm] 23.3" 2.0" [59.06cm] [5.08cm] TYP 19.0" 23.0" [48.26cm] [58.42cm] OBLIQUE 30°...
Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and dis- infecting an Oakworks table is a two part process. First it must be cleaned of any visible soil, then it can be disinfected. Oakworks recommends that the table be positioned in the flat position during the cleaning process.
INSPECTIONS / WARRANTY I N S P E C T I O N S RECOMMENDED REGULAR INSPECTIONS (monthly or local standard) • Check for damage to the power, hand control(s) and foot control(s) on all cables. • Check the hand/foot control for signs of wear or damage (replace if necessary). •...
U N I Q U E D E V I C E I D E N T I F I C A T I O N (U D I) I N F O R M A T I O N CFPM400 Table Manufacturer: GTIN 00817463021325 Oakworks, Inc. 923 East Wellspring Road Manuf. date: 2016-10-26 New Freedom, PA, USA 17349 FL4636744 +1 717-235-6807 www.oakworks.com...
50° (10°C) to 104° (40°C) 20% to 60% RH 98 to 105 kPa Storage & Transport -20° (-29°C) to 135° (57°C) 20% to 95% RH 98 to 105 kPa ELECTRICAL SPECIFICATIONS CFPM100 Tables Only All Other Tables Designed for: NORTH EUROPE NORTH EUROPE AMERICA...
IEC 61000-3-3 Recommended Separation Distances between the portable and mobile RF Communications equipment and the Oakworks Imaging and Pain Management Tables for Equipment and Systems that are NOT life-supporting The table is intended for use in the electromagnetic environment in which radiated RF disturbances are con- trolled.
P R O D U C T D I S P O S A L Disposal of the Oakworks Imaging and Pain Management Tables must be compliant with the appli- cable regulations and requirements of the local state environmental protection agency, state health agency, Centers for Disease Control (CDC), Occupational Safety and Health Administration (OSHA), U.S.