Summary of Contents for OAKWORKS Clinician Hydraulic
Page 1
USER MANUAL OAKWORKS ® Clinician Hydraulic Clinician Electric-Hydraulic Clinician Manual-Hydraulic 4-Section Lift-Assist Salon Top 4-Section Lift-Assist Salon Top Clinician Electric-Hydraulic Clinician Manual-Hydraulic 2-Section Lift-Assist Backrest Top 2-Section Lift-Assist Backrest Top Clinician Manual-Hydraulic Clinician Electric-Hydraulic 1-Section Flat Top 1-Section Flat Top...
Page 2
OAKWORKS , Inc. consequential damages in ® connection with or arising out of the furnishing, performance, or use OAKWORKS is a registered of this document and the program ® trademark of OAKWORKS , Inc. material which it describes. ®...
PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS PRODUCT USE DESCRIPTION Oakworks Clinician Electric-Hydraulic and Manual-Hydraulic Series offer a variety of positioning capabili- ties for massage therapists and spa professionals of all specialties. On these multifunctional professional tables the practitioner can perform numerous protocols with ease and comfort. The Clinician Electric- Hydraulic and Manual-Hydraulic Series are especially effective when professional protocols require spe- cific positioning for the client.
Page 5
Unplug from outlet before adding or removing parts. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use at 717.235.6807.
Do not sit on backrest or footrest section. The hood area under the backrest top is not designed for storage. DO NOT use this area for holding anything. Damage can occur to the table. The Oakworks Clinician Electric-Hydraulic Lift-Assist Salon Tables offer height and optional ABC posi- ®...
Do not sit on backrest section. The hood area under the backrest top is not designed for storage. DO NOT use this area for holding anything. Damage can occur to the table. The Oakworks Clinician Electric-Hydraulic Lift-Assist Backrest Tables offer height and optional ABC ®...
PRODUCT DESCRIPTION CONTROL OPERATIONS - FLAT TOP The Oakworks Clinician Electric-Hydraulic Flat Top Tables offer height and optional ABC positioning with ® electronic ease. Operate the foot control and/or optional hand control as shown below to raise or lower the height or optional ABC function of the table.
INSTALLATION All tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (See Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
DIRECTIONS FOR USE H Y D R A U L I C D A I L Y C Y C L I N G The Clinician Series uses hydraulics and hydraulic fluids to adjust the table height. Maintaining the quiet operation of your table requires that you fully cycle your table (up &...
DIRECTIONS FOR USE MANUAL-HYDRAULIC HEIGHT ADJUSTMENT To raise the table, unfold the crank handle until it locks into place. Turn the crank clockwise to raise the table to the desired height. To lower the table, turn the handle counter-clockwise. Raise table Lower table To fold handle out of the way, rotate until the handle is at its lowest point, then pull out slightly.
DIRECTIONS FOR USE LIFT-ASSIST BACKREST ADJUSTMENT CAUTION Do not sit on the backrest section. TO RAISE THE BACKREST: TO LOWER THE BACK REST: Raise the back rest by pressing the lever Press the lever under the head section and under the head section and lifting up to push the back rest down.
DIRECTIONS FOR USE MOVING THE TABLE Before moving the table, disconnect the power cord from the power outlet. The table weighs as much as 155 lbs. (70 kg.) Never lift the table by grasping the table top. You could damage the CAUTION table and the electronics that run the tabletop.
DIRECTIONS FOR USE R E M O V I N G T O P P A D The top pad has been designed to be easily removable and replaceable with no tools needed. IF THE TABLE HAS A HEATED TOP: Unplug the table from the wall outlet and disconnect the wires circled from the control box located under the platform.
Do not place foreign objects into the ABC System. Only use as intended. • For safety of your client, use a cloth sheet between the ABC System and your client. The Oakworks Adjustable Breast Comfort (ABC) System is designed to lower the pressure on breasts and pectoral ®...
DIRECTIONS FOR USE INTEGRATED HEATED TOP (OPTION) USING THE INTEGRATED HEATED TOP: The table comes with the option for a fully integrated dual zone heated top pad. Simply press the heating indicator(s) located on the right side rail of the table to the desired heat level. The heat can reach up to 40°C (105°F).
DIRECTIONS FOR USE QuickLock FACE REST: (ACCESSORY OPTION) • QuickLock Face Rest Weight Limit - 25 lbs (11.3 kg) CAUTION • Do not put excessive weight or pressure on the Face Rest. • Excessive pressure can cause premature failure of the Face Rest. Double articulating action provides nearly limitless positioning options with the QuickLock Face Rest.
DIRECTIONS FOR USE ADJUSTABLE SIDE ARM RESTS (ACCESSORY OPTION - SALON ONLY) • Do not use the arm rest for client support during the mounting or dismounting of the chair. CAUTION • The arm rest is not designed to support the client’s weight. TO INSTALL THE ARM RESTS: The Arm Rests adjust automatically as the back rest moves to remain parallel to the floor.
DIRECTIONS FOR USE BOIANCE SHELF SUPPORT: (ACCESSORY OPTION) • Boiance Shelf Support Weight Limit - 25 lbs (11.3 kg) CAUTION • Do not put excessive weight or pressure on the Boiance Shelf Support. • Excessive pressure can cause premature failure of Boiance Shelf Support. USING THE BOIANCE SHELF SUPPORT: The shelf and bracket used together allow you to create the perfect place for clients’...
DIRECTIONS FOR USE BLUETOOTH SPEAKER (ACCESSORY OPTION) BLUETOOTH SPEAKER ATTACHMENT: Located on the Face Rest Bracket on the underside of the head end of the table. Position Bluetooth Speaker with the magnetic attachment facing up. Plug the cord into the side of the speaker and attach it to the bracket. CONNECTING TO BLUETOOTH SPEAKER: Turn Bluetooth Speaker on by pressing the power button.
Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and disin- fecting an OAKWORKS ® table is a two part process. First it must be cleaned of any visible soil, then it can be disinfected. OAKWORKS ® recommends that the table be positioned in the flat position during the cleaning process.
INSPECTIONS / WARRANTY INSPECTIONS RECOMMENDED REGULAR INSPECTIONS (monthly or local standard) • Check for damage to the power, hand control(s) and foot control(s) on all cables. • Visually inspect components for obvious damage that could cause problems during operation. RECOMMENDED PERIODIC INSPECTIONS (yearly or local standard) •...
MODEL NUMBER & SERIAL NUMBER MODEL & SERIAL NUMBERS The model number and serial number are located on the underside of the foot section of the table top Model Number 16796025 CFSA4LF1T410USXXPW Ser#: CFK123456 06/03/2020 Order#:785461 Clinician Electric-Hydraulic LA Salon 1/T/4/11/US/XX/PW TT Stone Notes: XXX Serial Number Model and Serial numbers always start with a letter.
SPECIFICATIONS ENVIRONMENTAL CONDITIONS Conditions Temperature Humidity Atmospheric Pressure Normal Use 50° (10°C) to 104° (40°C) 20% to 60% RH 98 to 105 kPa Storage & Transport -20° (-29°C) to 135° (57°C) 20% to 95% RH 98 to 105 kPa ELECTRICAL SPECIFICATIONS Designed for: North America Europe...
USER MANUAL OAKWORKS ® Clinician Hydraulic CONTACT INFORMATION: Oakworks Inc. ® 923 East Wellspring Road New Freedom, PA 17349 Phone: 717.235.6807 FAX: 717.235.6798 www.oakworks.com 3034177 CONFORMS TO: UL STD 962 Certified to CAN/CSA STD C22.2 #68 Original Instructions Manual Part Number SPA-RA-PM-152...