OAKWORKS WOMEN’S IMAGING Instruction Manual

OAKWORKS WOMEN’S IMAGING Instruction Manual

Dual tower ultrasound tables

Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
OAKWORKS
®
Dual Tower Ultrasound Tables
MULTI-SPECIALTY
WOMEN'S IMAGING
ECHOCARDIOGRAPHY
GENERAL
GENERAL WITH FOWLER
GENERAL 3-SECTION
VASCULAR
VASCULAR WITH FOWLER
made in the USA
with US & imported parts
www.oakworksmed.com · 717.235.6807

Advertisement

Table of Contents
loading

Summary of Contents for OAKWORKS WOMEN’S IMAGING

  • Page 1 I N S T R U C T I O N M A N U A L OAKWORKS ® Dual Tower Ultrasound Tables MULTI-SPECIALTY WOMEN’S IMAGING ECHOCARDIOGRAPHY GENERAL GENERAL WITH FOWLER GENERAL 3-SECTION VASCULAR VASCULAR WITH FOWLER made in the USA with US &...
  • Page 2 OAKWORKS is a registered ® arising out of the furnishing, per- trademark of OAKWORKS , Inc. ® formance, or use of this document and the program material which it describes.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS Symbol Identification ....................1 Important Safety Instructions ................1 & 2 Section I: Product Description & Photo General & General with Fowler & General 3 Section ......3 Women’s Imaging ..................4 Multi-Specialty ................... 5 Echocardiography ..................
  • Page 4: Symbol Identification

    SYMBOL IDENTIFICATION SYMBOL IDENTIFICATION This symbol, when used in this manual and on product labels, represents a caution warning. Be sure to read and comply with all precautions and warnings. This symbol, when used in this manual and on product labels, warns against an electrical shock hazard.
  • Page 5 5. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use. 6. Keep the cord away from heated surfaces.
  • Page 6: General & General With Fowler & General 3 Section

    PRODUCT DESCRIPTION General Paper roll Shown with Optional Fowler (Backrest) holder (1) Upholstered Top Optional electric fowler (1) hand control Electric Lift Towers (2) Locking Casters (4) optional foot control INCLUDED FEATURES PRODUCT SPECS Electric Height Range: 22” - 38” PATIENT WEIGHT CAPACITY 600 lbs.
  • Page 7: Women's Imaging

    PRODUCT DESCRIPTION Paper roll holder (1) Women’s Imaging Electric fowler adjustable angle back support (Right side is standard) Electronic Lift hand control Towers (2) Adjustable Stirrups (2) Manual Adjustable Four Position Leg Section Locking Casters (4) optional foot control PRODUCT SPECS INCLUDED FEATURES Electric Height Range: 22”...
  • Page 8: Multi-Specialty

    PRODUCT DESCRIPTION Multi-Specialty Paper roll holder (1) adjustable angle back support (2) Electronic Lift Towers (2) Adjustable hand control Stirrups (2) Manual Central Base Adjustable Locking System Four Position Leg Section Locking Casters (4) foot control PRODUCT SPECS INCLUDED FEATURES Electric Height Range: 22”...
  • Page 9: Echocardiography

    PRODUCT DESCRIPTION Electric fowler Paper roll Echocardiography holder (1) Sliding Cardo Panel Electronic Lift adjustable Towers (2) angle back hand control support (Right side is standard) Locking Casters (4) foot control - manual cardio foot control - electric cardio PRODUCT SPECS INCLUDED FEATURES Electric Height Range: 22”...
  • Page 10: Vascular With Fowler

    PRODUCT DESCRIPTION Vascular with Fowler Paper roll holder (1) Electric fowler Patient Side Rail (2) Restraint Strap (1) hand control Electronic Lift Towers (2) Integrated Locking Foot Board (2) Casters (4) optional foot control PRODUCT SPECS INCLUDED FEATURES Electric Height Range: 23” - 40” PATIENT WEIGHT CAPACITY 600 lbs.
  • Page 11: Vascular

    PRODUCT DESCRIPTION Vascular Paper roll holder (1) Integrated Foot Board 2" or 4" position and easy drop away. 2" position 4" position Patient Restraint Strap (1) Side Rail (2) staggered anti-skid position surface Electronic Lift Towers (2) Integrated Locking Foot Board (2) Casters (4) optional foot control INCLUDED FEATURES...
  • Page 12: Section Ii: Installation

    INSTALLATION The Ultrasound tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
  • Page 13: Section Iii: Directions For Use

    DIRECTIONS FOR USE Controls: The Hand Control and optional Foot Control operates all functions of the table with the touch of a button. Follow the directions below to access these functions. HAND CONTROL OPERATIONS - GENERAL Tilt Controls Foot End Head End Tilt Control: Tilt Control:...
  • Page 14: (Multi-Specialty, Women's Imaging, General With Fowler)

    DIRECTIONS FOR USE HAND CONTROL OPERATIONS - MULTI-SPECIALTY, WOMAN’S IMAGING, GENERAL WITH FOWLER Foot End Foot End Head End Trendelenburg Control: Trendelenburg Control: activates tilt up to 15º activates tilt up to 15º positioning stops when positioning stops when table is level; press again table is level;...
  • Page 15: Control Operations (Tables With Electric Sliding Cardio Panel)

    DIRECTIONS FOR USE MULTI-SPECIALTY AND ECHOCARDIOGRAPHY WITH ELECETRIC SLIDING CARDIO PANEL Foot End Foot End Head End Trendelenburg Control: Trendelenburg Control: activates tilt up to 15º activates tilt up to 15º positioning stops when positioning stops when table is level; press again table is level;...
  • Page 16: Vascular Table With Fowler

    DIRECTIONS FOR USE VASCULAR TABLE WITH FOWLER Foot End Foot End Head End Trendelenburg Control: Trendelenburg Control: activates tilt up to 15º activates tilt up to 15º positioning stops when positioning stops when table is level; press again table is level; press again for complete reverse.
  • Page 17: Vascular Table Without Fowler

    DIRECTIONS FOR USE VASCULAR TABLE WITHOUT FOWLER Foot End Foot End Head End Trendelenburg Control: Trendelenburg Control: activates tilt up to 15º activates tilt up to 15º positioning stops when positioning stops when table is level; press again table is level; press again for complete reverse.
  • Page 18: Handset Safety Lock-Out

    DIRECTIONS FOR USE HANDSET SAFETY LOCK OUT (SPECIALTY TABLE ONLY) On specialty table models, there is a handset lock out located next to the siderail. WARNING For procedures where accidental table motion is a safety concern, the handset control must be locked-out.
  • Page 19: Adjustable Angle Back Support

    DIRECTIONS FOR USE ADJUSTABLE ANGLE BACK SUPPORT CAUTION Do not sit on Adjustable Angle Back Support. (Max Capacity 150 lbs.) TO RAISE BACK SUPPORT TO LOWER BACK SUPPORT Lift panel to desired angle. Panel will Press support bar against plastic plate automatically lock into nearest set and hold until back support is lowered point.
  • Page 20: Operating The Manual Adjustable 4 Position Leg Section

    DIRECTIONS FOR USE OPERATING THE MANUAL ADJUSTABLE FOUR POSITION LEG SECTION CAUTION TO LOWER THE LEG SECTION TO RAISE THE LEG SECTION Do not sit on the elevated Raise leg section above horizontal Raise the leg section by pulling it Back Rest or Leg Rest.
  • Page 21: Integrated Foot Board

    DIRECTIONS FOR USE INTEGRATED FOOT BOARD 2" position 4" position staggered anti-skid position surface CAUTION Mount & dismount table with the table in the flat position. Make sure footboards are securely positioned before patient places weight on them. TO RAISE FOOTBOARD TO 2” POSITION Grasp with one With footboard Grasp with one...
  • Page 22 DIRECTIONS FOR USE INTEGRATED FOOT BOARD (CONTINUED) TO MOVE FOOTBOARD FROM 2” TO 4” POSITION CAUTION When the footboards are in the down position, it is possible With second hand, Grasp rod at 90º Grasp rod at 90º for them to hit the ground in grasp footboard &...
  • Page 23: Patient Restraint Strap

    DIRECTIONS FOR USE PATIENT RESTRAINT STRAP FLAT TOP TABLES Install strap under rail attached to the top. NOTE: For Vascular tables, the strap is installed under the rail attached to the top, and above the second rail. CAUTION Use restraining strap above 30º...
  • Page 24: Paper Roll Holder

    DIRECTIONS FOR USE PAPER HOLDER USE To load the paper, pull down on Insert rod thru paper roll and place two paper holder support arms rod into the holes in the support arms. located on the under side of backrest. Rotate to 90º...
  • Page 25: Quicklock Face Rest

    DIRECTIONS FOR USE QUICKLOCK FACE REST * U.S. Patent #5,177,823 NOTE: Double articulating action provides nearly limitless positioning options You will need with the QuickLock Face Rest. The adjustable pad takes pressure off ™ an accessory mounting sensitive facial areas while providing superb support. The QuickLock ™...
  • Page 26: T-Rail Adapter

    Access/Back Support or Cardio Panels. DETACHABLE ARM BOARD This product can CAUTION be used on any of Oakworks ultrasound Do not put excessive weight or pressure on arm board. tables with a T-Rail Adapter and can support a variety of positioning...
  • Page 27: Foot & Hand Control Replacement

    TROUBLESHOOTING FOOT CONTROL REPLACEMENT INSTRUCTIONS Replacement of the foot control may be necessary if the foot control does not actuate the functions of elevation and the hand control is operational. See troubleshooting section for details. To replace the foot control, follow these steps: Unplug power cord.
  • Page 28: Section V: Troubleshooting

    IMPORTANT THERMAL LIMITING SWITCH The Oakworks Ultrasound tables have two lifting columns that raise and lower the table. In addition, the Multi-Specialty & Women’s Imaging have one actuator that allow the client to be positioned for both client and therapist comfort. Each of these devices has a duty cycle of approximately 10%, meaning 2 minutes of operation within a 20 minute period.
  • Page 29: Section Vi: Cleaning - Inspections & Maintenance

    CARE & CLEANING CLEANING TABLE Use only a mild detergent solution or 10% sodium hypochlorite solution on surfaces. Be sure excess liquid does not drip onto any other surfaces or mechanisms. Disinfectants other than recommended above will harm the table’s surface. Wipe off IMPORTANT excess with a lint-free cloth.
  • Page 30: Section Vii Product Identification

    PRODUCT IDENTIFICATION POWER LEAD PLUGS OAKWORKS Part #.: Voltage (AC) Power Cord Plug 5097-11 120v 60 Hz 3 prong grounded hospital grade; North America 5097-3 220v 50 Hz Continental Plug; Europe 5097-4 220v 50 Hz Swiss plug; Switzerland 5097-2 220v 50 Hz British plug;...
  • Page 31: Section Viii: Specifications

    SPECIFICATIONS Model No. All Models ELECTRICAL SPECIFICATIONS North America Europe Japan/Korea Designed For: Input Service 120 VAC/15amp/60Hz 220 VAC/10amps/50Hz 100 VAC/20amp/50-60-Hz Current Draw 4.0 amps 2.0 amps 4.8 amps Maximum Momentary Power 3.0 amps 7.2 amps 6.0 amps Consumption Voltage Output 24 VDC 24 VDC 24 VDC...
  • Page 32 SPECIFICATIONS Guidance and manufacturer’s declaration –electromagnetic emissions The Ultrasound Table is intended for use in the electromagnetic environment specified below. The customer or the user of the Ultrasound Table should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
  • Page 33 SPECIFICATIONS Guidance and manufacturer’s declaration –electromagnetic immunity The Ultrasound Table is intended for use in the electromagnetic environment specified below. The customer or the user of the Ultrasound Table should assure that it is used in such an environment. Electromagnetic environment Immunity test IEC 60601 test level Compliance level...
  • Page 34 SPECIFICATIONS Guidance and manufacturer’s declaration –electromagnetic immunity The Ultrasound Table is intended for use in the electromagnetic environment specified below. The customer or the user of the Ultrasound Table should assure that it is used in such an environment. Compliance –...
  • Page 35 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 36: Contact Information

    I N S T R U C T I O N M A N U A L OAKWORKS ® Dual Tower Ultrasound Tables CONTACT INFORMATION: Inc. ® AKWORKS 923 East Wellspring Road New Freedom, PA 17349 Toll Free (USA only): 800-916-4613...

Table of Contents