Page 3
Inc. ® akworks Inc. assumes responsi bility for errors that may appear in this documen t nor does it make expresse d or implied warranty of any kind with regard to this material, includin g, but limited to, the implied warranti es of merchant...
forman use of this docum ent and progra materia l which describ TABLE OF CONTENTS Symbol Identification ....................ii Warnings & Safety Instructions .................iii Grounding Instructions ....................v Section I: Product Description ™ Premiere Table Photo & Specifications ..........1 Section II: Installation Leveling Instructions ................
Page 5
Section VI: Product Identification ..............13 Section VII: Table Specifications................14 Section VIII: List of Parts ..................15 Section IX: Warranty ..................16 Contact Information ................back cover...
SYMBOL IDENTIFICATION SYMBOL IDENTIFICATION This symbol, when used in documentation on this product, represents a caution. Be sure to read and comply with all precautions and warnings. This symbol, when used in documentation on this product, indicates danger and warns against an electrical shock hazard.
Page 7
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Improper use of this device can cause injury. Be sure to read all operating instructions prior to use to prevent injury to operator or client. Electrical Shock Hazard. To reduce the risk of electric shock, always DANGER disconnect the table from the electrical outlet before moving the table or doing any maintenance or troubleshooting procedures.
Page 8
• Do not outdoors. • Do not operate where aerosol (spray) products are being used where oxygen is being administered. • Maximum shelf load weight: 200 lbs. (91kg.) – Risk of Injury Children should never near table when use. This table must be locked out (use key lock) and controls stored out of reach if there is any possibility that children would be...
any reason. To do so could cause damage to the base and will void the warranty. There are no serviceable items that require this action. Never lift the table by grasping the table top as the table top is not designed to hold the weight of the base and you could damage the table.
INSTRUCTIONS a grounding pin in a pattern that varies by country as shown in the Product Identification section of this manual. Make sure that the product is connected to an outlet having the same configuration as the plug. grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Page 11
™ Premiere TABLE SPECS* : • Height *: 25” - 35” • Width: 29” or 31” • Length: 73” • Lift Capacity: 500 lbs Maximum Working Load • Weight**: 157-182 lbs. (depends on model) Flat Top model shown here with optional hot towel cabi 1 Multi-Function Foot Control •...
* measurements are determined from floor to top of seat pad using standard padding; these measurements can be affected by natural material variations in padding ** published weight may differ due to options chosen, natural material variations and padding density INSTALLATION - LEVELING INSTRUCTIONS INSTALLATION INSTRUCTIONS: The Premiere...
DIRECTIONS FOR USE DAILY CYCLING ™ ™ The O Premiere uses hydraulics and hydraulic fluids to adjust Premiere controls and making any and all adjustments to the ® akworks table height. Maintaining the quiet operation of your table requires that you fully cycle your table (up table, move hands, feet and controls away from any work- &...
Page 14
Press and hold the appropriate button until the position desired is achieved and then release. The arm rests (available on Salon Top) will adjust automatically to provide the most in comfort and ergonomics while staying parallel to the floor, no matter what the position.
Page 15
To Access the Storage in the Under Table Cabinet: ™ The Premiere has a fully integrated wood cabinet and base. The large under-table cabinet provides storage for stacks of towels and other equipment without interfering with the lift capacity of the table.
DIRECTIONS FOR USE towel warmer or other electric devices. This allows you to store the unit inside with DANGER no excess cords to get in the way. With it plugged in, your towels stay warm and within easy reach, yet are still out of the way. You will find the plug inside the cabinet at the This product is equipped with an Premiere ™...
DIRECTIONS FOR USE UNDER-TABLE CABINET (cont) times when an optional electrical appliance such as a facial massager is used the ™ Premiere comes equipped with an opening to allow the cord of the appliance to pass through the cabinet and access the interior outlet, thus giving you complete power without the safety hazard and distraction of loose cords in the working area.
Page 19
DIRECTIONS FOR USE ARM REST INSTALLATION AND ADJUSTMENT INSTRUCTIONS 1. Insert end of arm rest into 2. Push end all the way into hole and drop arm rest into horizontal hole in backrest while holding position. Tug slightly to make sure the armrest is fully locked to arm rest at 60° angle. the table (for patient safety).
Page 20
DIRECTIONS FOR USE QuickLock FACE REST: ™ * U.S. Patent #5,177,823 CAUTION Do not put excessive weight or pressure on the face rest. Excessive pressure can cause premature failure of the QuickLock Face Rest. ™ Double articulating action provides nearly limitless positioning options with the QuickLock ™...
Page 21
so that the thick part of the pad supports your client’s cervical region. Adjusting the height and angle of the face rest gives your client perfectly comfortable support. CAUTION Do not put excessive weight or pressure on the face rest. Excessive pressure can cause premature failure of the QuickLock Face Rest...
Table Extender CAUTION Do not put excessive weight or pressure on the extender. Excessive pressure can cause premature failure of the Table Extender. The optional stationary Table Extender provides ultimate comfort for your tallest clients, quickly and easily. The Table Extender comes with two connecting arms that slide into the outlets at the foot end of the tabletop.
power cable is plugged in. Try all Foot Control Buttons to see if any work. If any work, then possibly there is a loose connection or a faulty controller. • Unplug the power cable from the wall outlet. • Make sure that all male and female connectors are firmly pushed into each other. Even a slight misconnection can cause a possible malfunction.
• Protect your table and BASE & CONTROLS • Use only a mild solution of 4:1 diluted non-alcohol cleaner such as 409 , Fantastik ® ® or some other non-abrasive cleaner to wipe down the metal and wooden surfaces. Apply with a damp (not wet) lint-free cloth. Be sure excess liquid does not drip onto, or into, any of the electrical controls or mechanisms.
Page 25
7791-02 220v 50 Hz British plug; United Kingdom 7791-06 220v 50 Hz Australian Plug; Australia SPECIFICATIONS Complies with: UL 962, CAN/CSA C22.2 No. 68-09, ETL listed EN60335-1, EN60335-2-32...
Page 26
North America Europe/Australia Designed For: Voltage/Current Service 220 VAC/ 1.6 amps Available 120 VAC/ 2.9 amps Input Frequency 50 Hz 60 Hz 12 amps max 6.5 amps max Current Consumption with internal Outlets 350 watts 350 watts Power Consumption Table Actuator Voltage 24 VDC 24 VDC Electric Shock Protection...
Page 27
Storage & Temperature: 32ºF - 100ºF Humidity: 60% relative humidity Pressure: no limitations known Transport 0ºC - 38ºC During transport, DO NOT stack containers. * measurements are determined from floor to top of seat pad using standard padding; these measurements can be affected by natural material variations in padding.
Page 28
WARRANTY STATEMENT For full warranty details, please visit www.oakworks.com All warranties are limited to factory-provided replacement parts, factory repair or replacement, at the discretion of O ® akworks All warranties exclude damage caused by improper set-up, accident, abuse, misuse, neglect, use for other than intended purpose or reasonable wear such as tears in the upholstery.
Page 29
CONTACT INFORMATION: Inc. ® akworks 923 East Wellspring Road New Freedom, PA 17349 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworks.com European Authorized Representative: Emergo Europe Molenstraat 15 The Hague, 2513 BH Netherlands Complies with: UL 962 CAN/CSA C22.2 No. 68-09 EN60335-1 3034177...
Need help?
Do you have a question about the Clinician Premiere Series and is the answer not in the manual?
Questions and answers