Page 2
OAKWORKS , Inc. tial damages in connection with or ® arising out of the furnishing, per- formance, or use of this document OAKWORKS is a registered and the program material which it ® trademark of OAKWORKS , Inc. describes. ®...
TABLE OF CONTENTS Product Use Description......................1 Important Safety Instructions Symbol Identification ..................... 1 Safety Instructions ...................... 2-3 Installation Grounding ........................4 Product Description & Photo Electric Salon ......................... 5 Control Operation - Electric Salon ................. 6 Flat Top ......................... 7 Control Operation - Flat Top ..................
There are no known contraindications to the use of this equipment. The Clinician Premiere should not be used in any other manner than that described within this manual. Use of any unnecessary force or unauthorized procedures could result in injury to practitioner, client or equipment.
2. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use at 717.235.6807. 3. Keep the cord away from heated surfaces.
Page 6
IMPORTANT SAFETY INSTRUCTIONS ENTRAPMENT • Risk of Injury - The picture below indicate areas of entrapment that can occur when operating this equip- ment. It is the responsibility of the operator to ensure that bystanders are not in or around these areas dur- ing operation.
INSTALLATION All tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (See Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the con- trols are located to your liking and are conveniently accessible.
PRODUCT DESCRIPTION Clinician Premiere Electric Salon STANDARD SPECIFICATIONS OPTIONS Motion 1 Powered 26”-36” (66-91 cm.) Height Range Adjustable Breast Comfort (ABC) System Motion 2 Powered 0-70º Backrest Wood Finishes Motion 3 Powered 0-30º Foot Rest Cabinet Door Material & Style...
DO NOT use this area for holding anything. Damage can occur to the table. The Clinician Premiere Electric Salon Tables offer height, backrest, footrest, and optional ABC positioning with electronic ease. Operate the foot and hand control as shown below to raise or lower the height, back- rest, footrest, or optional ABC functions of the table.
PRODUCT DESCRIPTION Clinician Premiere Flat Top STANDARD SPECIFICATIONS OPTIONS Motion 1 Powered 26”-36” (66-91 cm.) Height Range Adjustable Breast Comfort (ABC) System Foot Control All powered motions Wood Finishes Hand Control All powered motions Cabinet Door Material & Style Table Voltage Options...
C O N T R O L O P E R A T I O N S - F L A T T O P T A B L E S The Clinician Premiere Flat Top tables offer height positioning with electronic ease. Operate the foot and hand control as shown below to raise or lower the height of the table and operate the optional ABC.
DIRECTIONS FOR USE S T O R A G E C A B I N E T & I N-C A B I N E T O U T L E T This product is equipped with an interior 120-volt 60Hz six plug accessory outlet. The total electrical DANGER load of equipment plugged into this set of outlets is not to exceed 7 amps or 840 watts.
H Y D R A U L I C D A I L Y C Y C L I N G The Clinician Premiere uses hydraulics and hydraulic fluids to adjust the table height. Maintaining the quiet operation of your table requires that you fully cycle your table (up & down) twice per day. Cycling of the table will maintain the lubrication within the hydraulic cylinders for continued smooth and quiet operation.
DIRECTIONS FOR USE M O V I N G T H E T A B L E Before moving the table, disconnect the power cord from the power outlet. Secure the power cord CAUTION and all hand or foot controls before moving. The table weighs as much as 190 lbs. (86 kg.) Four people are required to move the table safely.
DIRECTIONS FOR USE R E M O V I N G T O P P A D The top pad has been designed to be easily removable and replaceable with no tools needed. IF THE TABLE HAS A HEATED TOP: Unplug the table from the wall outlet and disconnect the wires circled from the control box located under the platform.
Do not place foreign objects into the ABC System. Only use as intended. • For safety of your client, use a cloth sheet between the ABC System and your client. The OAKWORKS Adjustable Breast Comfort (ABC) System is designed to lower the pressure on breasts and pectoral ®...
DIRECTIONS FOR USE I N T E G R A T E D H E A T E D T O P (O P T I O N) USING THE INTEGRATED HEATED TOP: The table comes with the option for a fully integrated dual zone heated top pad. Simply press the heating indicator(s) located on the right side rail of the table to the desired heat level.
DIRECTIONS FOR USE QUICKLOCK F A C E R E S T: (A C C E S S O R Y O P T I O N) • QuickLock Face Rest Weight Limit - 25 lbs (11.3 kg) CAUTION • Do not put excessive weight or pressure on the Face Rest.
DIRECTIONS FOR USE ADJUSTABLE SIDE ARM RESTS (ACCESSORY OPTION - SALON ONLY) • Do not use the arm rest for client support during the mounting or dismounting of the chair. CAUTION • The arm rest is not designed to support the client’s weight. TO INSTALL THE ARM RESTS: The Arm Rests adjust automatically as the back rest moves to remain parallel to the floor.
DIRECTIONS FOR USE BOIANCE SHELF SUPPORT: (ACCESSORY OPTION) • Boiance Shelf Support Weight Limit - 25 lbs (11.3 kg) CAUTION • Do not put excessive weight or pressure on the Boiance Shelf Support. • Excessive pressure can cause premature failure of Boiance Shelf Support. USING THE BOIANCE SHELF SUPPORT: The shelf and bracket used together allow you to create the perfect place for clients’...
DIRECTIONS FOR USE BLUETOOTH SPEAKER (ACCESSORY OPTION) BLUETOOTH SPEAKER ATTACHMENT: Located on the Face Rest Bracket on the underside of the head end of the table. Position Bluetooth Speaker with the magnetic attachment facing up. Plug the cord into the side of the speaker and attach it to the bracket. CONNECTING TO BLUETOOTH SPEAKER: Turn Bluetooth Speaker on by pressing the power button.
TROUBLESHOOTING I F T H E T A B L E W I L L N O T C H A N G E H E I G H T O R P O S I T I O N Disconnect the power cord from the power outlet before doing any work on the unit.
Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and dis- infecting an Oakworks table is a two part process. First it must be cleaned of any visible soil, then it can be disinfected. Oakworks recommends that the table be positioned in the flat position during the cleaning process.
INSPECTIONS / WARRANTY I N S P E C T I O N S RECOMMENDED REGULAR INSPECTIONS (monthly or local standard) • Check for damage to the power, hand control(s) and foot control(s) on all cables. • Visually inspect components for obvious damage that could cause problems during operation. •...
Model Number 16796025 CPSA4EF1T411USXXPW Ser#: PAD123456 Clinician Premiere, 4 Sect SA/4EF/1/T/4/11/US/XX/PW TTStone 11/27/2019 Order#:654321 Serial Number Notes: Sample Product Label Model and Serial numbers always start with a letter.
SPECIFICATIONS C L I N I C I A N P R E M I E R E T A B L E D I M E N S I O N S CABINET DIMENSIONS Total Inside Dimensions: 48.2” L x 22.2” W x 14.0” H 122.4cm L x 57.2cm W x 35.6cm H Opening Dimensions: 20.0”...
SPECIFICATIONS ENVIRONMENTAL CONDITIONS Conditions Temperature Humidity Atmospheric Pressure Normal Use 50° (10°C) to 104° (40°C) 20% to 60% RH 98 to 105 kPa Storage & Transport -20° (-29°C) to 135° (57°C) 20% to 95% RH 98 to 105 kPa ELECTRICAL SPECIFICATIONS Designed for: North America Europe...
USER MANUAL OAKWORKS ® Clinician Premiere C O N T A C T I N F O R M A T I O N: Oakworks Inc. ® 923 East Wellspring Road New Freedom, PA 17349 Phone: 717.235.6807 FAX: 717.235.6798 www.oakworks.com...
Need help?
Do you have a question about the Clinician Premiere and is the answer not in the manual?
Questions and answers