Cleaning The Motor; Checking The Tightness Of Fastening Bolts - Siemens SIMOGEAR BA 2330 Operating Instructions Manual

Motors for mounting onto simogear gearboxes
Table of Contents

Advertisement

Service and maintenance
10.5 Checking the tightness of fastening bolts
10.4

Cleaning the motor

Explosion hazard due to overheating of the machine caused by a layer of dust
Deposits of dust have a thermally insulating effect, causing the machine to overheat. The
maximum surface temperature of the machine is not adhered to. The dust is ignited as a result,
causing an explosion. Death, serious injury and material damage will result.
• Regularly remove dust from the machine.
• Do not allow dust layers thicker than 5 mm to build up.
• Only switch the machine on when the dust has been removed.
NOTICE
Dust deposits cause higher housing temperatures
Dust deposits prevent heat from being radiated.
Keep the drive free from dirt and dust.
NOTICE
Cleaning with a high-pressure cleaning appliance
Water penetrates the geared motor. Seals are damaged.
Do not use a high-pressure cleaning appliance to clean the geared motor.
Do not use tools with sharp edges.
De-energize the drive unit when cleaning the drive unit.
10.5

Checking the tightness of fastening bolts

Note
Replace damaged headless bolts with new bolts of the same type and strength class.
Switch off the power supply to the drive unit. Check all fastening bolts for tightness using a
torque wrench.
94
WARNING
Motors for mounting onto SIMOGEAR gearboxes
Operating Instructions, 01/2024, A5E53220841A/RS-AA

Advertisement

Table of Contents
loading

Table of Contents