evertz 7700 Manual

Dual compressed ts automatic smart switch
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

Quick Links

1.
OVERVIEW ..................................................................................................................................... 5
2.
INSTALLATION OF 7780R2X1-ASI-CS-2...................................................................................... 7
2.1. REAR PLATE DESCRIPTION ...............................................................................................................7
2.1.1. ASI Connectors........................................................................................................... 7
2.1.2. Ethernet Connections ................................................................................................. 8
2.2. HARDWARE INSTALLATION ...............................................................................................................9
2.3. CONFIGURING THE BASIC NETWORK SETTINGS .........................................................................12
3.
TECHNICAL DESCRIPTION ........................................................................................................ 14
3.1. SPECIFICATIONS ................................................................................................................................14
3.1.1. General ..................................................................................................................... 14
3.1.2. Inputs and Outputs per switch .................................................................................. 14
3.1.3. Monitored Parameters TR 101 290........................................................................... 14
3.1.4. Tables and Repetition ............................................................................................... 14
3.1.5. PID Template ............................................................................................................ 15
3.1.6. Electrical ................................................................................................................... 15
3.1.7. Physical..................................................................................................................... 15
4.
REMOTE MONITORING/CONTROL....................................................................... 16
®
4.2. CONNECTING TO VLPRO ..................................................................................................................16
5.
CARD CONFIGURATION ............................................................................................................. 18
5.1. INPUT STATUS ....................................................................................................................................18
5.2. SWITCH CONTROL .............................................................................................................................19
5.2.1. Clean Switch A Controls ........................................................................................... 20
5.2.1.1. Switch Mode............................................................................................... 20
5.2.1.2. Switch Output Control ................................................................................ 20
5.2.1.3. GOP Repeat Mode..................................................................................... 20
5.2.2. Clean Switch A Settings............................................................................................ 21
5.2.2.1. Switch Method............................................................................................ 21
5.2.2.2. Stream Type............................................................................................... 21
5.2.2.3. Reset Switch .............................................................................................. 22
5.2.2.4. PCR Tolerance........................................................................................... 22
5.2.2.5. Switch Back Waiting Time.......................................................................... 22
5.2.2.6. Switch minimum delay ............................................................................... 23
5.2.2.7. Output ASI mode........................................................................................ 23
5.2.2.8. Low latency mode ...................................................................................... 23
5.2.3. Clean Switch A Information....................................................................................... 23
5.2.3.1. Stream Delay Info ...................................................................................... 23
5.2.3.2. Delayed Stream Info .................................................................................. 23
5.2.3.3. Splice Status .............................................................................................. 24
7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch

TABLE OF CONTENTS

? .......................................................................................................................16
®
Revision 1.4
7700 MultiFrame Manual
Page i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7700 and is the answer not in the manual?

Questions and answers

Summary of Contents for evertz 7700

  • Page 1: Table Of Contents

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch TABLE OF CONTENTS OVERVIEW ............................. 5 INSTALLATION OF 7780R2X1-ASI-CS-2..................7 2.1. REAR PLATE DESCRIPTION .......................7 2.1.1. ASI Connectors......................7 2.1.2. Ethernet Connections ....................8 2.2. HARDWARE INSTALLATION .......................9 2.3. CONFIGURING THE BASIC NETWORK SETTINGS .................12 TECHNICAL DESCRIPTION ......................
  • Page 2 7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2.3.4. Output Status ..................... 24 5.2.3.5. Switch Current delay .................. 24 5.2.4. Auto Reset ........................ 24 5.2.4.1. Based On PMT version ................24 5.2.4.2. Based On TSID ..................24 5.2.4.3. Based On Bitrate ..................25 5.3.
  • Page 3 ABBREVIATIONS......................... 53 Figures Figure 1-1: 7780R2x1-ASI-CS-2 Block Diagram ....................6 Figure 2-1: 7780R2x1-ASI-CS-2 Rear Plate ....................7 Figure 2-2: 7700 Chassis..........................9 Figure 2-3: COM Port Properties Window ......................10 Figure 2-4: HyperTerminal Main Menu ......................11 Figure 2-5: Network Configuration Sub-Menu ....................12 Figure 4-1: VistaLINK PRO Hardware Configuration..................17...
  • Page 4: 7780R2X1-Asi

    Evertz products are for informational use only and are not warranties of future performance, either expressed or implied. The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty, stated in the sales contract or order confirmation form.
  • Page 5: Overview

    Bitrate measurement on each PID • Display of Transport Stream tree • Matching of PID assignment, with predefined PID list and TSID • Complete customization of status view and error report in VistaLINK ® • Fits in 7700 Chassis Page Revision 1.4...
  • Page 6: Figure 1-1: 7780R2X1-Asi-Cs-2 Block Diagram

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch ASI Output 1 (Bypass Protected) ASI Output 1 ASI 1 A input Equalizer Cross Connect TS monitoring Smart switching 10/100/ 1000 RJ45 ASI 1B Equalizer TS monitoring input Controller Card...
  • Page 7: Installation Of 7780R2X1-Asi-Cs-2

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch INSTALLATION OF 7780R2X1-ASI-CS-2 2.1. REAR PLATE DESCRIPTION The 7780R2x1-ASI-CS-2 comes standard with a companion +3RU rear plate. Figure 2-1 provides an illustration of the 7780R2x1-ACI-CS-2 rear plate. For information on mounting the rear plate and inserting the module into the frame, see section 3 of the 7700FR manual.
  • Page 8: Ethernet Connections

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch ASI OUT 1 and ASI OUT 2: There are four BNC connectors with serial digital video outputs. The ASI OUT 1 to the ASI IN 1A and the ASI OUT 2 to the ASI IN 1B are bypass relay protected.
  • Page 9: Hardware Installation

    ESD strap be worn. Locate on a 7700 chassis three adjacent vacant slots. Unpack the 7780R2x1-ASI-CS-2 and separate the rear card from the main card. Locate on the rear of the rack the three slots and remove the blanking panels.
  • Page 10: Figure 2-3: Com Port Properties Window

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch This can be confirmed when the connectivity lights for the Ethernet port are illuminated. Do not connect any cables to the rear card (failure to do this could cause unwanted network issues) until the initial configuration has been completed.
  • Page 11: Figure 2-4: Hyperterminal Main Menu

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch Figure 2-4: HyperTerminal Main Menu (1) Network Configuration This sub-menu enables the user to configure the network settings for the card. (2) SNMP Configuration This sub-menu enables the user to configure the Simple Network Management Protocol settings. In this menu you can set or remove the SNMP trap IP address and the SNMP Read and Set community strings.
  • Page 12: Configuring The Basic Network Settings

    7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch (6) Engineering/Debug This menu is for Evertz personnel only. You may be requested to access and execute options within this menu when seeking technical support from Evertz. Guidance will be given should this be required.
  • Page 13 7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch From the Main Menu select option (2) SNMP Configuration. Normally it is only necessary to configure here, under option (1) Set Trap IP Address, enter here the IP address of your VLPro Server. Exit using option (s) Save and Exit, now extract the card from the rack, remove the serial cable and re-insert it.
  • Page 14: Technical Description

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch TECHNICAL DESCRIPTION 3.1. SPECIFICATIONS The 7780R2x1-ASI-CS-2 Dual ASI clean switch is designed for seamless switching between two identical ASI streams. 3.1.1. General • PCR re-stamping of the output • Second buffer, per clean switch up to 213M/bs •...
  • Page 15: Pid Template

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 3.1.5. PID Template • TSID • PID List • Bitrate Limits 3.1.6. Electrical Power: 3.1.7. Physical Number of Slots: Page Revision 1.4...
  • Page 16: Vistalink Remote Monitoring/Control

    ISTA ® VistaLINK is Evertz’ remote monitoring and configuration platform which operates over an Ethernet ® network using Simple Network Management Protocol (SNMP). SNMP is a standard computer network protocol that enables different devices sharing the same network to communicate with each other.
  • Page 17: Figure 4-1: Vistalink Pro Hardware Configuration

    VLPro communicates with the card and confirms its configuration. Please consult your network administrator if you continue to have problems connecting the card with VLPro, alternatively contact Evertz Microsystems Ltd. or your authorized reseller for technical support. Page Revision 1.4...
  • Page 18: Card Configuration

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch CARD CONFIGURATION 5.1. INPUT STATUS Right-click the IP address of the 7780R2x1-ASI-CS-2 in the sub-menu and select View Configuration. The right window will display the 7780R2x1-ASI-CS-2 Configuration menus as shown in Figure 5-1.
  • Page 19: Switch Control

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2. SWITCH CONTROL The Switch Control tab is for configuring the mode and method for both A and B clean switches. The controls are identical and independent for each. Both switches are identical in operation and configuration so for ease of illustration and explanation we will only consider switch A in this manual.
  • Page 20: Clean Switch A Controls

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2.1. Clean Switch A Controls 5.2.1.1. Switch Mode Switch Mode options are “Manual”, “Auto-Manual Return” and “Auto Switch”. Normal operating modes are “Auto Switch” or “Auto-Manual Return;” however, “Manual” can be used during engineering work for example to prevent switching.
  • Page 21: Clean Switch A Settings

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2.2. Clean Switch A Settings 5.2.2.1. Switch Method Options are “Packet Matching”, “GOP boundary” and “Packet Switch”. Here we select how the switch finds its switch points. The operation of these three modes has different effects on the output and the selection of which depends upon the inputs.
  • Page 22: Reset Switch

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch Note: It is important to select the correct mode for the stream configuration in use. • MPTS - SPTS: Options are SPTS or MPTS. In SPTS mode the PCR will be re-stamped on the output and should ideally be used in GOP Boundary mode.
  • Page 23: Switch Minimum Delay

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2.2.6. Switch minimum delay The standard time a signal spends in clean switch (Input to output delay) depends on multiple parameters such as input 1 to input 2 time difference, Bitrate, switching mode and how much time the streams spend in buffer.
  • Page 24: Splice Status

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2.3.3. Splice Status The status window is very important as it displays, when in auto-refresh mode, the near real-time status of the switch. If you are having problems, the display reads “Not ready to clean splice”, “Switch request pending”...
  • Page 25: Based On Bitrate

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.2.4.3. Based On Bitrate When this is enabled the clean switch will reset when a large input Bitrate is detected. The user can decide on a 20, 40, 60, 80% Bitrate change before applying the reset.
  • Page 26: Switch Faults

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.4. SWITCH FAULTS Figure 5-5: VistaLINK PRO Switch Faults ® 5.4.1. Switch A Output Status • Input 1 Sel On Output: Selecting this check box will cause VLPro to be notified, via an SNMP trap, that Input 1 has been selected as the output.
  • Page 27: Snmp Configuration

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 5.5. SNMP CONFIGURATION The SNMP Configuration tab is used to add or remove existing trap destinations. To add a trap destination simply enter the trap destination in the Destination IP Address field, then select the Apply button.
  • Page 28: Configuring Inputs

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch CONFIGURING INPUTS With the 7780R2x1-ASI-CS-2 hardware tree expanded, it is possible to see the sub components, in this case Input 1, Input 2, Input 3 and Input 4. By right clicking and selecting configure it is possible to configure each of the inputs completely independent of one another.
  • Page 29: Input Configuration Tab

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.2. INPUT CONFIGURATION TAB The Input Configuration tab is used to select the stream type being monitored. The Input Configuration tab also configures the PID and TS display options. Figure 6-2: VistaLINK PRO Input Configuration Tab ®...
  • Page 30: Input Monitor Tab

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.3. INPUT MONITOR TAB The Input Monitor tab provides the user with an overview of the input status. Figure 6-3: VistaLINK PRO Input Monitor Tab ® 6.3.1. Input Monitor Entry •...
  • Page 31: Error Monitor

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.3.2. Error Monitor • Input Status: This field displays a system message to notify the user if the input is receiving a valid ASI source. • Syntax Error Status: This field displays s system message to notify the user if any of the ETSI TR 101 290 P1/P2/P3 monitoring tests are currently in an alarm condition.
  • Page 32: Syntax Errors - P1 & P2

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.4. SYNTAX ERRORS – P1 & P2 The Syntax Errors – P1 & P2 tab displays a general health check for the most important elements of the TS. The tests are not exhaustive and are outlined in detail in the document Digital Video Broadcasting (DVB);...
  • Page 33: P1 Necessary For Decoding

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch The following chart provides a list of controls that apply to both Priority 1 and Priority 2 tables: Indicates the status of each test. Green indicates that no faults are found and Status red indicates that a fault is found.
  • Page 34: Clear P1 Errors

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch • PMT Error: The Program Association Table (PAT) tells the decoder how many programs there are in the stream and points to the PMTs that contain the information where the parts for any given event can be found.
  • Page 35: Switch Controls

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.4.3. Switch Controls Switch Controls apply to both P1 and P2 tables in this section. Enabling a parameter or number of parameters is very simple. Add a threshold value (see Figure 6-5) next to the test in the threshold box located to the very right of the page.
  • Page 36: Ts Syntax Errors - P3

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch Note: Forced switching in some conditions, with GOP repeat disabled, will require a soft reset to restore the switches capability to clean switch between sources. • Threshold: This field enables the user to enter a threshold value.
  • Page 37: P3 Dvb Tables

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch The following chart provides a list of controls that apply to both Priority 3 DVB Tables and Priority 3 ATSC Tables: Indicates the status of each test. Green indicates that no faults are found and Status red indicates that a fault is found.
  • Page 38: P3 Atsc Tables

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch • RST Repetition: This test checks that any two sections with table_id = 0x71 (RST) occur on PID 0x0013 within 25 ms (or lower). • RST Error: The RST is a quick updating mechanism for the status information carried in the EIT.
  • Page 39: Switch Controls

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.5.3. Switch Controls Switch Controls apply to both P3 DVB and P3 ATSC tables in this section. Enabling a parameter or number of parameters is very simple. Add a threshold value (see Figure 6-7) next to the test in the threshold box located to the very right of the page.
  • Page 40: P3 Clear Error Control

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.5.4. P3 Clear Error Control Priority 3 Errors can be reset at any time by selecting the “Clear P3 Errors” drop down box and selecting the “Clear” option. Once the setting is applied, using the apply button, all error displays will be reset.
  • Page 41: Template Check

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.7. TEMPLATE CHECK The Template Check tab offers full customization of the switch to individual streams. Careful consideration is needed to correctly configure the switch to avoid unnecessary switching. Figure 6-8: VistaLINK PRO Template Check Tab ®...
  • Page 42: Global Control

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch o Splice: When the error condition occurs the switch will only occur where a clean switch point is available. If no switch point is currently available then the switch will cancel the request to preserve service quality (Ideally this should be used where the impact of the error is minor).
  • Page 43: Windows Measurement

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.7.5. Windows Measurement The window measurement values determine at what interval each PID (within the PID List Template) should be expected before an alarm condition is met. • Windows Measurement 1 (ms): Enter a decimal value, measurement is in milliseconds.
  • Page 44: Fault Control

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch • Reset PID Template: This button can be used to reset the PID List. All entries will be set to “NOT SET”, all Windows Measurements (WM) set to “Off” and the Switch Method will also be set to “Off”.
  • Page 45: Trigger Faults Tab

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 6.9. TRIGGER FAULTS TAB The Trigger Control tab provides a user configurable custom configuration for the top-level alarm statuses. This can be used to provide quick visual overviews of the ETSI TR 101 290 test status. An operator would need to refer either to the TS Syntax Error Tabs and review the status LED’s, or to the...
  • Page 46: Troubleshooting

    7.2. UPDATING VLPRO SERVER JAR FILE Products from Evertz are constantly evolving and new features are often added. It is therefore important to update the JAR files in use to provide access to all the latest features or enhancements. It will also be necessary to add JAR files for new products.
  • Page 47: Figure 7-2: Vistalink Pro Applying Jar Updates

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch Figure 7-2: VistaLINK PRO Applying JAR Updates ® You will be prompted to restart the server to enable the change to take effect. Apply as many JAR updates as required before restarting the server.
  • Page 48: Switching Logic

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 7.3. SWITCHING LOGIC 7.3.1. Special Cases • Packet Matching: By definition the Packet Matching mode requires two identical streams within which it finds matching points for cleanly switching inputs. From start-up the card therefore requires two valid matching streams.
  • Page 49: Gop Repeat Mode - Disabled

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 7.3.2. GOP Repeat Mode – Disabled Current Switch Current Switch Error Output Action Output Action Switch point Total Loss INP1 INP2 Loss of INP1 INP1 INP2 INP2 Clean Switch Loss of INP2...
  • Page 50: Table 7-1: Gop Repeat Mode - Disabled

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch Switch point Total Loss INP1 INP2 No switching Loss of INP1 INP1 INP2 No switching Loss of INP2 INP1 INP2 No switching Manual Mode PS Syntax Switch Request Clean INP1...
  • Page 51: Gop Repeat Mode - Enabled

    7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch 7.3.3. GOP Repeat Mode – Enabled Current Switch Current Switch Error Output Action Output Action Switch point Total Loss INP1 INP2 GOP Repeat Loss of INP1 INP1 INP2 INP2 Clean Switch...
  • Page 52: My Streams Are More Than 3 Seconds Delayed

    The buffering capability of the 7780R2x1-ASI-CS-2 is limited to 3 seconds per switch. If the streams arrive more than 3 seconds apart then it will be necessary to install a 7780DLY-ASI which can delay an ASI stream up to 16 seconds. Please contact Evertz or an Evertz reseller for further information. Page...
  • Page 53: Abbreviations

    7780R2x1-ASI-CS-2 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch ABBREVIATIONS For the purposes of the present document, the following abbreviations apply: Bouquet Association Table Bit Error Rate Band Width Conditional Access Conditional Access Table Common Phase Error Cyclic Redundancy Check European Telecommunications Standards Institute ETSI Direct Current Digital Video Broadcasting...
  • Page 54 7700 MultiFrame Manual 7780R2x1-ASI-CS-2 Dual Compressed TS Automatic Smart Switch This page left intentionally blank Page Revision 1.4...

This manual is also suitable for:

7780r2x1-asi-cs-27780r2x1-asi-cs

Table of Contents