SELECTING WHETHER THE GENLOCK REFERENCE INPUT IS TERMINATED

TERM:
The TERM jumper J17 located at the rear of the module is used to terminate the
genlock loop input. Then it is in the 75R position a 75 ohm terminating resistor will
connect the input to ground. When it is in the HI-Z position the genlock input will be
high impedance.
7.4.

CONTROLLING GPI PULLUP VOLTAGE

Jumper J16, located at the rear of the module controls whether the GPI inputs are pulled up to 5 volts or
12 volts.
GPI SELECT:
To pull the GPI inputs to 12 volts install this jumper in the position closest to edge of
the module.
To pull the GPI inputs to 5 volts install this jumper in the position closest to centre of
the module.