4.13
PREVENTIVE MAINTENANCE
( Book 35386598, 8J92)
r----
STRAIGHTEDGE (B)
TANK COVER (E)
--j
(/
![~
II I I
I
I
IJ
1 1 1
I
I I
1
I
1 1
I
I
I I I_I
L
' f -ooI~__ --
ELEMENT (C)
"X"
~
lL___..-------,---,r-
J
i
I
,
--S-- -
CUT LINE IF NECESSARY
"YII
--
SEPARATOR TANK (A)
L-
----'
Ftgure 4.1 Element Measurement
~--
SCAVENGE TUBE (0)
Figure 4.2 Tube Measurement
• Ensure the tank pressure is zero
The life of the oil separator element is dependent upon the operating enviro~-
ment (soot, dust, etc.) and should be replaced every twelve months or appropn-
ate hours of operation basis (See PM Schedule on page 4.16).
To
replace the
element proceed as follows:
• Disconnect the hose from the scavenge
tube.
• Remove scavenge tube from tank cover.
• Disconnect service line from cover.
• Remove (16) cover mounting screws.
• Remove cover, element and inner shell.
• Remove any gasket material left on cover or tank.
• Install new element, with new gasket, and inner shell in separator tank
(A).
continued
-
-
-
- -
- -
-
-
-
..