Hounneter - Records running time for maintenance purposes.
8.
Voltmeter - Indicates battery condition.
9.
Engine Water Temperature Gauge -
Indicates coolant
temperature, with normal operating range from
1£'O°F{82°C)
to
21 O°F(99°C).
CONTROLS
10. Power Switch - Flip "On" to operate, "Off'to stop.
11. Lights Switch - Operates Lamp 2 and those within gauges.
12. Heaters Switch - Activates control system heaters for
operation below
32°F(°C).
13. Service Air Button - After warm up. provides full air pressure
at the service outlet.
14. Bypass Button - Bypasses automatic shutdown circuit.
15. Start Button - Activates the engine starter.
16. Ether Inject Button - Injects a measured shot.
USE SPARINGLY.
DIAGNOSTICS / AUTOMATIC SHUTDOWN
17. High Compressor
Temperature
-
248°F(120°C)
or more.
18. Low Engine
011
Pressure -
12
psi or less.
19. High Engine Ternperature
s-
Coolant above 215°F (102°C).
20. Low Fuel Level-
Comes on first as a warning and
eventually triggers a shutdown.
21. Altemator Not Charging - Needs attention.
22. Low Coolant Level-
Dangerously low; needs attention.
23. Air Filters Restricted - Need servicing.