2.9 PRESET

Presets are pre-defined setups for such things as Matte settings, Safe Area/Title display, Transition
settings and Key/Fill input. The parameters for the settings are stored based on the status of the
program bus. Therefore if you would like to set a preset that has a mask aspect of 2.35, you must first
set the mask. Then store the preset at the required address. All Recalled presets are recalled to the
Preview Bus and will not show on the program bus until the Transition button is pushed, or a GPI
trigger invokes the transition.
Recall Preset: Select from 1 to 10 to reload previously saved settings.
Store Preset: Select from 1 to 10 to save the current settings (Whatever the units preview bus is
configured for will be saved).
Export Preset: This menu item is used to send the settings to one of the ten user presets to the
console serial port (UPGRADE 232) as ASCII text. This function is useful to archiving the settings of
the presets or for diagnostic purposes.
Use the
or
buttons to select the preset that you want to export. When you press the SELECT
button the settings will be sent as ASCII text to the UPGRADE 232 serial port.
To capture these
settings you can use any terminal program such as HyperTerminal. Then use the Text capture
function of your terminal program to save the ASCII text.
Preset Source: This menu item is used to select the source of the preset settings. Select store
preview to use the preview buss as the source of the preset settings. Select store program to use the
program buss as the source of the preset settings.
GPI Setup: There are 2 types of GPI triggers. The "Mode" setting in each GPI can be set to either
Level or Pulse. Level is the traditional setting for the GPI triggers, where the On Closure event
happens when the GPI drives the input pin low to ground. The On Separation event occurs when the
GPI releases the level to the +3.3 setting again.
The new Pulse mode toggles the On Closure and On Separation events whenever the pin signal is
driven low. For example, drive the pin to ground and release the pin will invoke the On Closure event,
then drive the pin to ground again and release the pin to invoke the on Separation event.
GPIs can be configured to trigger 2 events, On Closure and On Separation. Use the Up/Down arrow to
move the cursor to the desired GPI A-H, and press the Select button to configure the desired GPI.
The On Closure event can be used to load a Preset and perform a transition. The On Separation event
for the same GPI can be used to load a Preset and perform a transition. The menu system can be
traversed using the Up/Down arrow to select the desired menu item and the Select button to jump to
programmable options for that item. Use the Up/Down arrows to scroll the available options and press
the Select key to accept your selection. When you are done press the Setup button to exit the
configuration mode and press the Select button again to save the changes and exit the Preset setup
page.
GPI A to H: All DSK units.
GPO Setup: GPO A - D: All DSK units.