Wrong communications port selected in the terminal program.
Improper port settings in the terminal program. Refer to step 4 for settings.
Evertz frame is off.
The cursor under the line "Upload main program" should be replicating across the screen.
While the cursor is replicating press the <CTRL> and <X> keys, this should stop the cursor from
replicating. If the Evertz frame continues to boot-up simply cycle the power on the Evertz frame and
repeat this step.
Type the word "upgrade", without quotes, and hit the <ENTER> key once.
You should now see a prompt asking you to upload the file. "Upload main program"
For example:
Upload cancelled
Entering command loop
>upgrade
Upload main program
Part IV – Uploading the new firmware
Upload the "*.bin" file supplied using the X-Modem transfer protocol.
16. The boot code will indicate whether the operation was successful upon completion of the upload.
For Example:
UPLOAD OKAY
>
16. The following is a list of possible reason for a failed upload:
If you get the message "transfer cancelled by remote" you must restart the terminal program and load
the bin file using the method outlined in Part III – Invoke upload mode via the terminal program.
The supplied "*.bin" file is corrupt.
Wrong file specified to be uploaded.
The PCs' RS-232 communications port can't handle a port speed of 57600.
Noise induced into the RS-232 "straight-thru" serial extension cable.
To ensure proper communications use step 9 to break out of the boot up sequence and type the word
help. You should get back some text. This confirms that you are sending data, receiving data and are
locked to 57600.
Firmware Update Procedure
Revision 1.0
HD9626DSK Instruction Manual
Page 5-3