4. Configure the port settings of the terminal program as follows:
Baud
57600
Parity
no
Data bits
8
Stop bits
2
Flow Control
None
5. Power-up the Evertz frame.
5.2.2. Part II – Invoke upload mode via the front panel
Note: If you cannot invoke the upload mode via the front panel outlined in Part II
then follow the steps in Part III.
•
Press the SETUP button once.
•
Press the down arrow until the main display reads General.
•
Press the SELECT button once.
•
Press the down arrow until the main display reads Update code.
•
Press the SELECT button once.
•
The main display should now show the message Yes-Upgrade Now.
•
Press the SELECT button to confirm the Upgrade operation, press Setup to cancel.
•
Skip to step 12.
5.2.3. Part III – Invoke upload mode via the Terminal Program
6. A banner with the boot code version information should appear in the terminal window.
For example:
EVERTZ 7700FC BOOT MONITOR.
MON8240 1.1 BUILD 9.
COPYRIGHT 2000 EVERTZ MICROSYSTEMS LTD.
UPLOAD MAIN PROGRAM
7. The following is a list of possible reasons for failed communications:
•
Defective RS-232 "straight-thru" serial extension cable.
•
Wrong communications port selected in the terminal program.
•
Improper port settings in the terminal program. Refer to step 4 for settings.
•
Evertz frame is off.
8. The cursor under the line "Upload main program" should be replicating across the screen.
Page 5-2